Guardian Technologies PN 8402 User Manual
Page 6

READY LIGHT
l
On when all system functions
are O.K.
l
Fast blink for burglary violation.
. Slow blink when trouble or
alarm memory information is
displayed in windows.
* Off when a perimeter hardwire
AC POWER LIGHT
Indicates system has
AC power.
FIRE ALARM KEYS
AUX KEY & LIGHT * KEY
burglary loop is unsecured.
AWAY LIGHT
On when the system
is armed to AWAY
mode.
Note: Both STAY and
AWAY lights are on in
NIGHT mode.
STAY LIGHT
On when the system is
armed to STAY mode.
Note: Both STAY and
AWAY lights are on in
NIGHT mode.
What the Messages in the Display Windows Mean
ALARM IDENTIFICATION (press and hold * key to erase)
(See “System Information” for locations)
A 01 thru A 52
A H1 thru A H8
A HF
A HP
A HE
FIRE TROUBLE
F 33 thru F 40
F H1 thru F H8
BYPASSING
b H1 thru b H8
u H1 thru u H8
b 01 thru b 04
SYSTEM TROUBLE
E 01 thru E32
E AC
E Fu
E bb
E EE
Transmitter #
Hardwire Zone #
Master Keypad Fire Alarm
Master Keypad Police Alarm
Master Keypad “AUX” key
when set to medical
RF Smoke Detector Low Battery
Hardwire Smoke Detector Trouble
Bypassed Hardwire Burglary Zone
Unsecure Hardwire Burglary Zone
Bypassed RF Channel
Channel # of Low Transmitter Battery
Replace battery or call installer.
AC Power Loss -Try to ascertain
cause (breakers, general outage,
etc.). As last resort call installer.
Blown Fuse in Control Center
Control Center Backup Battery
Trouble
Memory Error
System integrity is compromised. Call installer immediately.
Disabled
AUX key set for
. Press to silence recurring
45-second protest tones.
. Press and hold until 2nd beep to
User Code Required
clear alarm memory and
transmitter low battery indication.
AWAY KEY
Press to arm system to AWAY
Press then enter user code to arm
system to AWAY mode.
STAY KEY
Press once to arm system to STAY
Press again to arm system to
NIGHT mode.
Press once followed by user code to
arm system to STAY mode.
Press once followed by user code to
arm system to NIGHT mode.
CHIME MODE
l
Press and hold until 2nd
beep to view.
-
Enter user code within 8
seconds to change.
TEST MODE
-
Press and hold until 2nd
. Enter user code (‘8 88’ will
flash in windows).
l
Press 1 to exit test mode.
BYPASS BURGLARY
PROTECTION
Disabled
-
-
-
- -
-
-
0 Transmitters
Zones
l
Press and hold until
2nd beep.
* Enter user code.
l
Press xmtr/zone #.
RESET HARDWIRE
SMOKE DETECTORS
* Press and hold until 2nd
beep.
Not used.
9
ADD/CHANGE 2nd USER
CODE
-
Press and hold until 2nd
beep, then enter MASTER
user code.
Key in 2nd user code
within 10 seconds.
8
.