beautypg.com

Iring, Iagram, Roduct – Goodman Mfg SS-GPH13MC User Manual

Page 15: Pecifications, Arning

background image

14

www.goodmanmfg.com

SS-GPH13MC

SS-GPH13MC

www.goodmanmfg.com

15

P

roduct

S

PecificationS

P

roduct

S

PecificationS

w

iring

d

iagraM

— gph1348-60M43**

Wiring

is

subject

to

change.

Al

wa

ys

refer

to

the

wiring

diag

ram

or

the

unit

for

the

most

up-to-da

te

wiring

.

W

arning

High

Voltage:

Disconnect

all

power

bef

or

e

ser

vicing

or

installing

this

unit.

Multiple

power

sour

ces

ma

y

be

pr

esent.

F

ailur

e

to

do

so

ma

y

cause

pr

operty

damage,

per

sonal

injur

y,

or

dea

th.

SEE NOTE 6

BK

CH

CH

3

CONTROL
BOX

240

RD RD

RD

PU

2

24V

208

TR

C

BK

1

PU

COMP

CM

BR

BR

PU

4

1

PLF

PU

BK

S

BK

BK

5

6

2

3

C R

LVJB

RD

OR

BL

BR

WH

GR

YL

R

O

C

W2

W1

G

A
T

O

T

S

M

R

E

H

T

BL

PU

GND

BK

/

/

0

4

2

-

8

0

2

7

8

9

BL

BR

BK

BK

RD

PU

C L G N

1 2 3

BL

BL

BL

RD

GR

GR

GR

WH

RD

EM

GR

SEE NOTE 2

DFT

RVC



SEE UNIT RATING PLATE FO R TYPE AND SIZE

OF OVER CURRENT PROTECTION

COMPONENT LEGEND

WIRE CODE

BK BLACK
BL BLUE
BR BROWN
GR GREEN
OR ORANGE
PU PURPLE
RD RED
WH WHITE
YL YELLOW

FACTORY WIRING

LINE VOLTAGE
LOW VOLTAGE
OPTIONAL HIGH
VOLTAGE

FIELD WIRING

HIGH VOLTAGE
LOW VOLTAGE

SEE NOTE 5

BK

BK

BK

OR

OR

GR

YL

4 5

HPS

LPS

YL/PK

RD

RD

CHS

BK

PU

BK

PU

BL/PK

BL/PK

YL/PK

PU

YL

YL

PU

YL

YL

BL

WH

3

CONTROL
BOX

240

RD

RD RD

RD

RD

BK

BR

PU

2

24V

208

TR

C

1

PU

COMP

CM

BR

BR

PU

4

1

PLF

PU

BK

S

BK

BK

5

6

2

3

C R

LVJB

RD

OR

BL

BR

WH

GR

YL

R

O

C

W2

W1

G

Y/Y2

A
T

O

T

S

M

R

E

H

T

BL

SEE NOTE 3

PU

GND

BK

60

/

/

3

0

4

2

-

8

0

2

7

8

9

BL

BR

WH

0140G01744-B

RD

BK

BK

PU

C L G N

1 2 3

BL

BL

BL

RD

GR

GR

GR

WH

RD

EM

GR

SEE NOTE 2

DFT

RVC



SEE UNIT RATING PLATE FO R TYPE AND SIZE

OF OVER CURRENT PROTECTION

COMPONENT LEGEND

C
CCR
CH
CHS
CM
COMP
DC
DFT
EM
GND
HVDR
LPS
LVDR
LVJB
PLF
RVC
TR
HPS

CONTACTOR
COMPRESSOR CONTACTOR RELAY
CRANKCASE HEATER
CRANKCASE HEATER SWITCH
CONDENSER MOTOR
COMPRESSOR
DEFROST CONTROL
DEFROST THERMOSTAT
EVAPORATOR MOTOR
EQUIPMENT GROUND
HIGH VOLTAGE DEFROST RELAY
LOW PRESSURE SWITCH
LOW VOLTAGE DEFROST RELAY
LOW VOLTAGE JUNCTION BOX
FEMALE PLUG / CONNECTOR
REVERSING VAVLE COIL
TRANSFORMER
HIGH PRESSURE SWITCH

WIRE CODE

BK BLACK
BL BLUE
BR BROWN
GR GREEN
OR ORANGE
PU PURPLE
RD RED
WH WHITE
YL YELLOW

FACTORY WIRING

LINE VOLTAGE
LOW VOLTAGE
OPTIONAL HIGH
VOLTAGE

FIELD WIRING

HIGH VOLTAGE
LOW VOLTAGE

NOTES:

1. REPLACEMENT WIRE MUST BE SAME SIZE AND TYPE INSULATION AS
ORIGINAL (AT LEAST 105°C) USE COPPER CONDUCTOR ONLY.
2. TO CHANGE EVAPORATOR MOTOR SPEED MOVE WHITE AND YELLOW
LEADS FROM EM"2" AND "3" TO "4" AND "5". IF BOTH LEADS ARE
ENERGIZED, THE HIGHER SPEED SETTING IS USED.
3 FOR 208 VOLT TRANSFORMER OPERATION MOVE PURPLE W IRES FROM
TERMINAL 3 TO TERMINAL 2 ON TRANSFORMER.
4. START A SSIST FACTORY EQUIPPED WHEN REQUIRED
5. USE COPPER CONDUCTORS ONLY
++ USE N.E.C. CLASS 2 WIRE
6. CRANKCASE HEATER AND CRANKCASE HEATER SWITCH FACTORY
INSTALLE D OPTION.
7. ECONOMIZER PLUG LOCATED IN THE RETURN AIR COMPARTMENT.
REMOVE MALE PLUG, ATTACH FEMALE PLUG TO THE ECONOMIZER
ACCESSORY

.

SEE NOTE 5

BK

BK

BK

OR

OR

GR

YL

WH

4 5

HPS

LPS

BL

YL/PK

PU

BK

RD

PU

PU

SEE
NOTE 6

RD

RD

CHS

BK

PU

BK

PU

PU

BL/PK

BL/PK

YL/PK

PU

YL

YL

WH

PU

PU

YL

YL

BL

6

3

5

2

4

1

T2

L1

L2

T1

C

T3

L3

PU

Y

YL

YL

PU

YL

OR

BL

C-RV

O-RV

DFT

R-DFT

O

W

R

PS2

R-PS1

CNT

LPS

RVC

R

C

Y

DFT

DC

24V

SEE NOTE 2

3

2

THERMOSTAT

C

HPS

C

1 EM

PLF

6

5

4

C

G

Y/Y2

O

W2

R

G

2

3

1

1

L2

DF2

C

T2

HVDR

CM

F

C

DF1

L1

T1

COMP

C

SUPPLY VOLTAGE

208-240

TR

EM

SEE NOTE 3

SEE NOTE 2

3

2

C-RV

O-RV

DFT

R-DFT

O

W

R

PS2

R-PS1

CNT

LPS

RVC

R

C

Y

DFT

DC

24V

SEE NOTE 2

3

2

C

HPS

C

1 EM

PLF

6

5

4

SEE NOTE 6

CHS

CH

G

L

2

3

1

N

1

L2

DF2

C

T2

HVDR

CM

F

C

DF1

L1

T1

T1

COMP

C

SUPPLY VOLTAGE

208-240/3/60

208-240

TR

EM

SEE NOTE 3

SEE NOTE 2

3

2

L3

C

C

T2

T2

T3

6

3

5

2

4

1

Y1

W1

FC

GR

GR

BL

BK

RD

YL

YL

RD

RD

T3

GR

BL

PS2

C

C

R

C

Y

Y

R

-P

S

1

R-DF

T

D

FT

0

CNT

CCR

HVDR

LVDR

W

C-RV

0-RV

0

D

F2

D

F1

R

D

C

YL

YL

RD