Wiring diagrams, Iring, Iagram – Goodman Mfg SS-GPH13MC User Manual
Page 14: Roduct, Pecifications, Arning

14
www.goodmanmfg.com
SS-GPH13MC
SS-GPH13MC
www.goodmanmfg.com
15
P
roduct
S
PecificationS
P
roduct
S
PecificationS
w
iring
d
iagraM
— gph1336M43**
Wiring
is
subject
to
change.
Al
wa
ys
refer
to
the
wiring
diag
ram
or
the
unit
for
the
most
up-to-da
te
wiring
.
⚠
W
arning
High
Voltage:
Disconnect
all
power
bef
or
e
ser
vicing
or
installing
this
unit.
Multiple
power
sour
ces
ma
y
be
pr
esent.
F
ailur
e
to
do
so
ma
y
cause
pr
operty
damage,
per
sonal
injur
y,
or
dea
th.
⚡
WH
3
CONTROL
BOX
240
PU
BR
BK
BK
BK
RD
RD
BK
RD
RD
BK
BK
K1
K1
M1
NOTE #2
XFMR-C
PU
C
BL
XFMR-R
R
G
EBTDR
GR
COM
BL
PU
NC
RD
NO
RD
2
24V
BL
208
TR
C
BK
1
PU
COMP
CM
BR
BR
PU
4
1
PLF1
PU
BK
YL
S
BK
RD
BK
5
6
2
3
C R
RD
OR
BL
BR
WH
GR
YL
R
O
C
W2
W1
G
Y/Y2
A
T
O
T
S
M
R
E
H
T
SEE NOTE 4
PU
GND
6
0
/
/
3
0
4
2
-
8
0
2
HIGH
(TRANS240V)
PU
(M1) RD
BR
FC
LOW
OPTIONAL
2 SPEED
BR
EM
3 SPEED
EM
M2
7
8
9
BL
BR
WH
BK
BK
RD
PU
BK
BK
RD
DFT
RVC
LVJB
OR
OR
BL
BL
SEE NOTE
#6
BK
BK
PU
BL
BR
BK
(COM) BK
4
2
1
3
BK
HPS
LPS
CH
GR
BK
BK
RD
RD
CHS
PU
YL/PK
YL/PK
PU
SEE NOTE #3
SEE NOTE #3
BL/PK
PU
YL
YL
PU
PU
YL
BL/PK
PU
Y1
YL
RD
YL
FC
T2
L1
L2
T1
C
T3
L3
GR
L1
L2
0140G01737-B
COMPONENT LEGEND
BR
C
CCR
CH
CHS
CM
COMP
DC
DFT
EBTDR
EM
FC
GND
HPS
HVDR
LPS
LVDR
LVJB
PLF
RVC
TR
BLOWER INTERLOCK RELAY
CONTACTOR
COMPRESSOR CONTACTOR RELAY
CRANKCASE HEATER
CRANKCASE HEATER SWITCH
CONDENSER MOTOR
COMPRESSOR
DEFROST CONTROL
DEFROST THERMOSTAT
ELECTRONIC BLOWER TIME DELAY RELAY
EVAPORATOR MOTOR
FAN CAPACITOR
EQUIPMENT GROUND
HIGH PRESSURE SWITCH
HIGH VOLTAGE DEFROST RELAY
LOW PRESSURE SWITCH
LOW VOLTAGE DEFROST RELAY
LOW VOLTAGE JUNCTION BOX
FEMALE PLUG / CONNECTOR
REVERSING VALVE COIL
TRANSFORMER
WIRE CODE
BK BLACK
BL BLUE
BR BROWN
GR GREEN
OR ORANGE
PU PURPLE
RD RED
WH WHITE
YL YELLOW
FACTORY WIRING
LINE VOLTAGE
LOW VOLTAGE
OPTIONAL HIGH
VOLTAGE
FIELD WIRING
HIGH VOLTAGE
LOW VOLTAGE
R
G
C
EBTDR
THERMOSTAT
R
W2
O
W1
G
C
C
Y/Y2
SEE UNIT RATING PLATE FOR TYPE AND SIZE
OF OVER CURRENT PROTECTION
NOTES:
1. REPLACEMENT WIRE MUST BE SAME SIZE AND TYPE INSULATION AS
ORIGINAL (AT LEAST 105°C) USE COPPER CONDUCTOR ONLY.
2. TO CHANGE EVAPORATOR MOTOR SPEED REPLACE LEAD ON EBTDR
"COM" WITH LEAD ON EBTDR "M1" OR "M2".
3. CRANKCASE HEATER AND CRANKCASE HEATER SWITCH FACTORY
INSTALLED OPTION.
4. FOR 208 VOLT TRANSFORMER OPERATION MOVE PURPLE WIRES
FROM TERMINAL 3 TERMINAL 2 ON TRANSFORMER.
5. START ASSIST FACTORY EQUIPPED WHEN REQUIRED.
6. USE COPPER CONDUCTORS ONLY ++ USE N.E.C. CLASS 2 WIRE.
7. ECONOMIZER PLUG LOCATED IN THE RETURN AIR COMPARTMENT.
REMOVE MALE PLUG, ATTACH FEMALE PLUG TO THE ECONOMIZER
ACCESSORY.
HPS
LPS
L3
C
Y1
DC
Y
PLF1
6
5
4
RD
RD
R
R
DFT
DFT
R-DFT
PS2
R-PS1
CNT
C
O
W
C-RV
O-RV
RVC
FC
RD
BR
PU
BL
YL
YL
PU
OR
YL
6
3
5
2
4
1
BK
BL
BL
BL
P
L
F
1
BR
1
3
3
1
4
2
2
1
3
EBTDR
M2
N
O
EBTDR
NC
208-240
24V
TR
COM
M1
EM
SEE
NOTE 2
FC
SEE NOTE 4
PLF2
SUPPLY VOLTAGE
208-240/3/60
CM
T3
T2
SEE NOTE 3
CHS
DF2
C
CH
T2
HVDR
F
C
DF1
T1
T1
COMP
C
C
PLF2
PS2
C
C
R
C
Y
Y
R
-PS1
R-
DF
T
DF
T
0
CNT
CCR
HVDR
LVDR
W
C-RV
0-RV
0
DF
2
DF
1
R
D
C
PU
RD
YL
YL
6
3
5
2
4
1