Cooling Capacity
AHRI Cooling Capacity (BTU/h)
40,500
40,500
46,000
46,000
57,000
57,000
Sensible BTU/h
29,600
29,600
35,400
35,400
40,500
40,500
SEER / EER
14.0 / 12.0
14.0 / 12.0
14.0 / 12.0
14.0 / 12.0
14.0 / 12
14.0 / 12
Decibels
78
78
80
80
80
80
AHRI Numbers
4385135
5677877
4385136
5677878
4385137
TBD
Heating Capacity
BTU/h (47°F)
37,600
37,600
44,000
44,000
54,500
54,500
C.O.P. (47°F)
3.8
3.8
3.8
3.8
3.6
3.6
BTU/h (17°F)
21,600
21,600
26,000
26,000
33,800
33,800
C.O.P. (17°F)
2.4
2.4
2.4
2.4
2.5
2.5
HSPF
8.0
8.0
8.0
8.0
8.0
8.0
Evaporator Motor
Type
EEM
EEM
EEM
EEM
EEM
EEM
Wheel (D x W)
10 x 8
10 x 8
10 x 8
10 x 8
11 x 8
11 x 8
Cooling CFM
1,300
1,300
1,600
1,600
1,700
1,700
Fan-Only CFM
1,200
1,200
1,400
1,400
1,600
1,600
RLA
2.9
2.9
2.9
2.9
2.9
2.9
No. of Speeds
5
5
5
5
5
5
Horsepower - RPM
½ - 1,050
½ - 1,050
¾ - 1,050
¾ - 1,050
¾ - 1,050
¾ - 1,050
Evaporator Coil
Face Area (ft
2
)
6.2
6.2
6.2
6.2
7.0
7.0
Rows Deep/ Fins per Inch
4/ 14
4/ 14
4/ 14
4/ 14
4/ 14
4/ 14
Indoor Metering Device Size
0.072
0.074
0.076
0.076
0.088
0.088
Filter Size (ft
2
)
(2) 20x20x1
(2) 20x20x1
(2) 20x20x1
(2) 20x20x1
(2) 20x25x1
(2) 20x25x1
Drain Size (NPT)
¾"
¾"
¾"
¾"
¾"
¾"
Refrigerant Charge (oz.)
150
140
190
190
200
200
Condenser Fan / Coil
Horsepower - RPM
¼ - 1075
¼ - 1075
¼ - 1075
¼ - 1075
¼ - 1075
¼ - 1075
RLA/LRA
1.4 / 2.9
1.4 / 2.9
1.4 / 2.9
1.4 / 2.9
1.4 / 2.9
1.4 / 2.9
Fan Diameter / # Fan Blades
22 / 4
22 / 4
22 / 4
22 / 4
22 / 4
22 / 4
Face Area (ft
2
)
17
17
19.1
19.1
19.1
19.1
Outdoor Metering Device Size
0.065
0.065
0.065
0.062
0.071
0.071
Rows Deep/ Fins per Inch
1 / 24
1 / 24
2 / 16
2 / 16
2 / 16
2 / 16
Compressor
Quantity / Type
1 / Scroll / Single 1 / Scroll / Single 1 / Scroll / Single 1 / Scroll / Single 1 / Scroll / Single 1 / Scroll / Single
Compressor RLA/LRA
17.9 / 112
17.9 / 112
19.9 / 109
19.9 / 109
26.4 / 134
26.4 / 134
Electrical Data
Voltage/Phase/ Frequency
208-230/1/60
208-230/1/60
208-230/1/60
208-230/1/60
208-230/1/60
208-230/1/60
Indoor Blower FLA
2.9
2.9
2.9
2.9
2.9
2.9
Outdoor Fan RLA
1.4
1.4
1.4
1.4
1.4
1.4
Total Unit Amps
22.2
22.2
24.2
24.2
30.7
30.7
Min. Circuit Ampacity¹
26.6
26.6
29.2
29.2
40.2
40.2
Min. Overcurrent Protection (amps)²
40
40
45
45
60
60
Operating & Ship Weights (lbs)
375 / 385
375 / 385
405 / 415
405 / 415
405 / 415
405 / 415
¹ Wire size should be determined in accordance with National Electrical Codes. Extensive wire runs will require larger wire sizes.
² Must use time-delay fuses or HACR-type circuit breakers of the same size as noted.
Note: Always check the S&R plate for electrical data on the unit being installed.