3.3.3.8 Side Lobe Suppression

1. Set the SLS / ECHO toggle switch to the OFF position.
2. Adjust the RF level on ATC-1400A to MTL so that the XPDR%REPLY is 90%.
3. Raise the RF level to 3 dB above the MTL.
4. Set the SLS / ECHO thumb wheel switch to 0dB.
5. Flip the SLS / ECHO toggle switch to the ON position. The GTX 320 % Reply shall have an average reading

of 1% or less.
6. Raise the RF level on the ATC-1400A to MTL +50 dB. The GTX 320 % Reply shall have an average reading of

1% or less.

______ < 1% Reply (Average Reading)

3.3.3.9 External Suppression

With the unit replying to interrogations, apply a positive external suppression pulse of up to 100 microseconds

and with a voltage amplitude of greater than 8.0 volts. The unit must suppress the replies to any interrogations

received during the time of the suppression pulse.

______ OK

3.3.3.10 External Altittude Encoder Inputs

1. Set the digital oscilloscope to the following settings:

PARAMETER

SET POINT

EXT TRIG

CH 2 (XMTR Detected Video)

CH 2 VERTICAL SENS

20MV/DIV

HORIZONTAL SWEEP

5µS

DELAYED SWEEP

CENTER ON FIRST PULSE

2. Set the XPDR MODE switch on the ATC-1400A to position C. The oscilloscope shall display the P1 and P3

pulses similar to Figure 3-3. ______ OK

3. Rotate each of the four rotary switches on the GTX320 under test through at least one complete turn, stopping

on zero. The unit shall not transmit any code information as evidenced by a change in the P1 and P3 pulse

patterns. The XPDR CODE digital display on the ATC-1400A test set shall indicate 0000. ______ OK

4. Rotate the mode select switch on the GTX320 under test to the ALT position. ______ OK