beautypg.com

Imensions, Erformance, Atings – Goodman Mfg SS-CPKF50 User Manual

Page 2: Omenclature

background image

P

roduct

S

PecificationS

P

roduct

S

PecificationS

SS-CPKF50

www.goodmanmfg.com 3

2 www.goodmanmfg.com

SS-CPKF50

d

imenSionS

H

W

D

Model

Width

Depth

Height

CPKF24-2*

26

26

29¾

CPKF36-2/5*

26

26

32¼

CPKF42-5*

29

29

32¼

CPKF48-5*

29

29

32¼

CPKF60-5*

29

29

38¼

CPKF61-5*

29

29

38¼

P

erformance

r

atingS

Model #

Coil / Air Han-

dler

Cooling Capacity (BTU/h)

Heating Capacity (BTU/h)

dBs

Total

Sensible

EER¹

kWI²

47°F

47°F COP

HSPF³

17°F

17°F COP

CPKF24-2*

A24-00-2RA

23,400

16,400

9.0

2.60

23,000

2.8

7.0

12,400

2.00

78

CPKF36-2/5*

A36-00-2RA

33,000

24,100

9.0

3.67

32,000

2.9

7.2

17,400

2.00

78

A48-00-2RA

35,000

25,900

9.0

3.89

32,000

3.0

7.5

19,000

2.30

78

CPKF42-5*

A48-00-2RA

40,000

30,700

9.0

4.44

39,000

3.1

7.8

21,400

2.00

78

CPKF48-5*

A48-00-2RA

48,000

34,600

9.0

5.33

48,000

3.3

8.2

29600

2.30

78

CPKF60-5*

A60-00-2RA

53,000

36,600

9.0

5.89

54,000

3.2

8.0

35,400

2.10

80

CPKF61-5*

A60-00-2RA

57,000

38,800

9.0

6.33

61,000

3.0

8.0

37,800

2.20

80

¹ Energy Efficiency Ratio @ 80°F / 67°F / 95°F
² kWI = Compressor + Indoor Blower + Outdoor Fan Watts
³ HSPF = Heating Seasonal Performance Factor
Note: When mix-matching outdoor and indoor units, the indoor unit check-flowrator must match the outdoor unit size.

n

omenclature

Product Category

Engineering

C

Split System

Major/ Minor Revisions

Unit Type

E

Commercial Air Conditioner

Electrical

K

Air Conditioner

1

208/230 V, 1 Phase, 60 Hz

P

Heat Pump

2

220/240 V, 1 Phase, 50 Hz

3

208/230 V, 3 Phase, 60 Hz

Nominal Capacity

4

460 V, 3 Phase, 60 Hz

018 1½ Tons

048 4 Tons

5

380/415 V, 3 Phase, 50 Hz

024 2 Tons

060 5 Tons

030 2½ Tons

090 7½ tons

036 3 Tons

120 10 Tons

042 3½ Tons

PKF

2,3,4

036

5,6,7

8

1

9,10

1

C

AA