Pump, Ge 8, Removal – Graco 258906 User Manual
Page 8: Installation

Pump
8
3A0246C
Pump
Removal
1.
Perform Pressure Relief Procedure, see page 4.
2.
Remove Power Module, see page 7.
3.
Disconnect material hose (79) from pump (18a).
4.
Loosen two screws (40) and remove pump rod 
shield (48).
5.
Turn flow control knob to a very low setting and turn 
prime valve handle to TOOL FILL position (JOG 
mode will appear in display). Use ON/OFF switch or 
turn control knob OFF to stop pump when pin is 
visible. 
6.
Use screwdriver to press pin (7b) out of pump.
NOTE: Pin should be removed by pressing the pin 
out through the bottom side of the pump. Make sure 
to control the pump pin when removing so that it 
does not fall into the pump module.
7.
Use hammer to loosen pump retaining nut (22).
8.
Unscrew and remove pump (18a) from module.
Installation
1.
Extend pump piston rod 1.5 in.
2.
Install pump pin (7b). Verify retaining spring is in 
groove of connecting rod.
NOTE: Pin should be installed from the top side of the 
pump. Make sure to control the pump pin when installing 
so that it does not fall into the pump module.