Cleaning procedures – Grindmaster TEA-300 User Manual
Page 7
American Metal Ware
®
Tea Brewers
Page 6
Timer Adjustment (cont.)
3. This timer is adjustable from 15 seconds to 8 minutes.
4. Make the desired adjustments by turning the adjusting knob clockwise to increase timer setting; turning counter
clockwise to reduce time.
5. Re-install top cover with screw then plug unit in, return to use.
Thermostat Adjustment
Change thermostat setting if spray over water temperature requires adjustment. Factory setting is 195°F (90.56°C).
This is the ideal temperature for brewing tea. Water should never boil in the tank. If water is boiling in the tank,
adjust the temperature appropriately.
1. Shut off power and unplug the brewer.
2. Remove the screw fastening the top cover. Remove the top cover
by pulling forward and upwards.
3. Locate thermostat mounted on tank.
4. Turn the shaft clockwise to increase the water temperature, counter
clockwise to decrease water temperature. (Refer to Figure B.)
5. Re-install top cover with screw then plug unit in and return to use.
Bypass Adjustment
Change bypass adjustment if desired volume of brewed liquid requires
adjustment.
1. Shut off power and unplug the brewer.
2. Remove the lower front panel by removing the screws securing the panel.
3. Make the desired adjustments by turning the adjusting knob clockwise
to decrease the total brewed volume; turning counter clockwise to
increase volume.
Cleaning Procedures
Cleaning After Each Brew
Dispose of used tealeaves and rinse brew basket.
Figure B
Figure C
!
WARNING: BURN HAZARD
HOT LIQUIDS AND SURFACES ARE PRESENT IN THIS EQUIPMENT. TO AVOID BURNS
USE CAUTION WHEN CLEANING. RINSE HOT PARTS WITH COLD WATER BEFORE
CLEANING. USE GLOVES OR HEAVY CLOTH WHEN REMOVING HOT PARTS FROM
BREWER.