Model g3619, Model g9963 – Grizzly G9966 User Manual
Page 7

24" & 27" Resaw Bandsaws
-5-
Model G3619
The Model G3619 Bandsaw is pre-wired for sin-
gle-phase, 220V operation. Under normal use, the 
Model G3619 5 HP motor draws approximately 
22 amps. We recommend a 30 amp circuit. This 
includes a 30 amp circuit breaker and wiring rated 
for at least 30 amps. This should be satisfactory 
for normal use, while providing enough protection 
against damage caused by an overloaded circuit. 
If frequent circuit failures occur when using the 
bandsaw, contact our service department or your 
local electrical contractor.
This bandsaw must be connected to its own 
dedicated circuit; it should not share a circuit with 
any other machine. A standard 2-pole breaker is 
necessary for use with the Model G3619.
This bandsaw is not supplied with a power plug. 
We recommend using a NEMA-style L6-30 plug 
and outlet similar to 
Figure 1. You may also “hard-
wire” the bandsaw directly to your panel, provided 
you place a disconnect near the machine.
SECTION 2: CIRCUIT REQUIREMENTS
Figure 1. Typical 220V 3-prong plug and outlet.
Be sure that your particular electrical con-
figuration complies with local and state
codes. The best way to ensure compliance
is to check with your local municipality or a
licensed electrician.
Model G9963
The Model G9963 Bandsaw is pre-wired for 
single-phase, 220V operation. Under normal use, 
the Model G9963 7.5 HP motor draws approxi-
mately 33 amps. We recommend using a 50 amp 
circuit. This includes a 50 amp circuit breaker 
and wiring rated for at least 50 amps. If frequent 
circuit failures occur when using the bandsaw, 
contact our service department or your local elec-
trical contractor.
This bandsaw must be connected to its own 
dedicated circuit; it should not share a circuit with 
any other machine. A standard 2-pole breaker is 
necessary for use with the Model G9963.
This bandsaw is not supplied with a power plug. 
We recommend “hard-wiring” the bandsaw to the 
power source, provided you place a locking shut 
off switch near the machine to disconnect the 
power.