Dimensions and flue pipe, Stockton 8, Stockton 7 inset convector – Stovax STOV1008 User Manual
Page 33: Stockton 7, Stockton 8 inset convector, Stockton 8 double sided, Stockton 8 slimline 2 door

Dimensions and Flue Pipe
Connects with 6” flue pipe using:
Size
With
Without
door
door
1’ straight
4604
4600
2’ straight
4605
4601
3’ straight
4606
4602
1’ 3” – 2’ 1”
(telescopic) 4642
3’ 4” – 4’ 6”
(telescopic) 4640
Tee piece with
end cap
4616
Weight: 120kg - 126kg
23
3/4
” 603mm
14
3/8
” 366mm
6” 152mm
19
1/2
”
495mm
16
1/4
” 411mm
5
5
/8
”
141mm
4
1/8
”
105mm
Stockton 8
Maximum heat output for
single and 2 door with
‘clip-in’ boiler:
To boiler 4.4kW (15,000 btu’s)
To room 3.6kW (12,200 btu’s)
Total 8kW (27,200 btu’s)
24
3
/8
”
6
2
0
m
m
35
7
/8
”
9
11mm
2
9
3/
4
” 758m
m
24
1/2
” 624mm
13
1/4
” 336mm
11
3
/8
”
2
90
mm
8
3
/4
”
222mm
Weight: 120kg
Connects to register plate, flexible
flue liner or flue pipe. See installation
instructions.
19
1/4
”489mm
4
3/4
”
120mm
1
9
1
/4
”
4
90
m
m
2
1” 535m
m
13
1/2
”
345mm
1
5
/8
”
4
0
m
m
Stockton 7 Inset Convector
4
1
/2
”
11
3
mm
8
5/8
”
220mm
6”
150mm
15
3/4
”400mm
20
7/8
” 529mm
23” 582mm
6
” 1
50
mm
4
3
/8
”
120m
m
8
5
/8
”
220mm
21
1/8
” 536mm
22” 580m
m
15
1/4
” 385mm
4
3/
4
”
121mm
17
7
/8
”
455mm
13
3/8
” 341mm
4
1/8
”
105mm
6” 152mm
10
1/4
” 259mm
8
” 2
0
2mm
1
1
1
/4
” 2
86
m
m
Connects with 6” flue pipe using:
Size
With
Without
door
door
1’ straight
4604
4600
2’ straight
4605
4601
3’ straight
4606
4602
1’ 3” – 2’ 1”
(telescopic) 4642
3’ 4” – 4’ 6”
(telescopic) 4640
Tee piece with
end cap
4616
Weight: 130kg
Stockton 7
Maximum heat output:
To boiler 3.5kW (12,000 btu’s)
To room 3.5kW (11,800 btu’s)
Total 7kW (23,800 btu’s)
64
Maximum heat output
for single and 2 door with
integral boiler:
To boiler 4kW (13,600 btu’s)
To room 4kW (13,600 btu’s)
Total 8kW (27,400 btu’s)
3/
4
”
20m
m
Flue pipe connects your stove to the existing/new chimney system. The chimney system must meet the requirements of Building Regulations
(Document J) and the stove fitted in accordance with the detailed installation instructions provided with each unit. You may also download these
instructions prior to purchase from www.stovax.com.
11
1/4
” 288mm
18
3/4
”
474mm
13
1/4
” 338mm
4
1/8
”
105mm
23
3/4
” 603mm
23
3/
8
”
598
mm
4
3
/4
”
119m
m
6” 152mm
Weight: 120kg
Stockton 8 Inset Convector
Weight: 120kg
24
5/8
” 627mm
1
9
5
/8
”
500
mm
1
5/8
”
4
0
m
m
13
3/4
” 350mm
21
1
/2
” 550m
m
8
1/2
”
216mm
21
5/8
” 550mm
26” 660mm
6
1/2
”
164m
m
Stockton 8 Double Sided
5
3/8
”
135m
m
5”
126mm
28
1/2
” 724mm
8
1/2
”
216m
m
5
”
126mm
2
1
1
/2
”
547mm
3
/4
”
20mm
6
1/2
”
164mm
Weight: 120kg
Stockton 8 Slimline 2 Door
Connects with 6” flue pipe using:
Size
With
Without
door
door
1’ straight
4604
4600
2’ straight
4605
4601
3’ straight
4606
4602
1’ 3” – 2’ 1”
(telescopic) 4642
3’ 4” – 4’ 6”
(telescopic) 4640
Tee piece with
end cap
4616
65
Connects with 6” flue pipe using:
Size
With
Without
door
door
1’ straight
4604
4600
2’ straight
4605
4601
3’ straight
4606
4602
1’ 3” – 2’ 1”
(telescopic) 4642
3’ 4” – 4’ 6”
(telescopic) 4640
Tee piece with
end cap
4616
Connects to register plate, flexible
flue liner or flue pipe. See installation
instructions.
23
3/4
” 603mm
16
3/8
” 417mm
20” 507m
5
1
/2
” 140m
m
8
1/4
”
209mm
24
3
/8
”
6
2
0
m
m
35
5
/8
”
905
mm
24
3/4
” 628mm
15
1/4
” 388mm
Flue pipe connects your stove to the existing/new chimney system. The chimney system must meet the requirements of Building Regulations
(Document J) and the stove fitted in accordance with the detailed installation instructions provided with each unit. You may also download these
instructions prior to purchase from www.stovax.com.