beautypg.com

Dimensions and flue pipe – Stovax STOV1008 User Manual

Page 32

background image

Dimensions and Flue Pipe

Weight: 76kg

Connects with 5” flue pipe using:

Size

With

Without

door

door

1’ straight

4504

4500

2’ straight

4505

4501

3’ straight

4506

4502

1’ 3” – 2’ 1”
(telescopic) 4542

3’ 4” – 4’ 6”
(telescopic) 4540

Tee piece with
end cap

4516

62

15

1/4

” 389mm

11

1⁄2

” 291mm

5” 127mm

20

1/

8

5

1

0

m

m

15

7

/8

4

05

mm

13

1/4

” 338mm

3

3

/4

96

mm

3

1/2

90mm

Connects with 5” flue pipe using:

Size

With

Without

door

door

1’ straight

4504

4500

2’ straight

4505

4501

3’ straight

4506

4502

1’ 3” – 2’ 1”
(telescopic) 4542

3’ 4” – 4’ 6”
(telescopic) 4540

Tee piece with
end cap

4516

Weight: 83kg

15

1/4

” 389mm

11

1⁄2

” 291mm

5” 127mm

22

1/2

5

72m

m

18

1/4

4

65

m

m

13

1/4

” 338mm

3

3/4

96

m

m

3

1/2

90mm

Connects with 5” flue pipe using:

Size

With

Without

door

door

1’ straight

4504

4500

2’ straight

4505

4501

3’ straight

4506

4502

1’ 3” – 2’ 1”
(telescopic) 4542

3’ 4” – 4’ 6”
(telescopic) 4540

Tee piece with
end cap

4516

12” 306mm

5” 127mm

17

1

/4

4

36

m

m

13

1/4

” 335mm

4

3/4

1

20

m

m

3

1/2

90mm

Weight: 83kg - 90kg

19” 481mm

19

3/4

” 503mm

21

3

/8

” 544m

m

2

7

1

/2

” 685m

m

Stockton 3

Stockton 4

Stockton 5

Flue pipe connects your stove to the existing/new chimney system. The chimney system must meet the requirements of Building Regulations

(Document J) and the stove fitted in accordance with the detailed installation instructions provided with each unit. You may also download these

instructions prior to purchase from www.stovax.com.

A

Connects with 5” flue pipe using:

Size

With

Without

door

door

1’ straight

4504

4500

2’ straight

4505

4501

3’ straight

4506

4502

1’ 3” – 2’ 1”
(telescopic) 4542

3’ 4” – 4’ 6”
(telescopic) 4540

Tee piece with
end cap

4516

Maximum heat output:
To boiler 2.9kW (10,000 btu’s)
To room 3.1kW (10,400 btu’s)
Total 6kW (20,400 btu’s)

Connects with 5” flue pipe using:

Size

With

Without

door

door

1’ straight

4504

4500

2’ straight

4505

4501

3’ straight

4506

4502

1’ 3” – 2’ 1”
(telescopic) 4542

3’ 4” – 4’ 6”
(telescopic) 4540

Tee piece with
end cap

4516

Maximum heat output:
To boiler 2.9kW (10,000 btu’s)
To room 3.1kW (10,400 btu’s)
Total 6kW (20,400 btu’s)

Weight: 140kg

Weight: 130kg

18” 456mm

2

4”

609

mm

4

3/4

120mm

15” 380mm

1

9

3

/4

50

1mm

13

1/4

” 339mm

3

1/2

90mm

5” 127mm

10

5/8

” 270mm

8

5/8

” 21

8

m

m

1

0

1/2

2

6

7m

m

5” 127mm

13

1/4

” 339mm

3

1/2

90mm

18” 456mm

40

1

/4

1020m

m

30

1/

8

7

65

m

m

1

0

3/8

263

m

m

15” 380mm

35

7/8

9

1

3

mm

14

3/

4

375mm

10

1/2

26

7m

m

Stockton 6

Stockton 6 Highline

Weight: 100kg

Stockton 5 Midline

63

Connects with 5” flue pipe using:

Size

With

Without

door

door

1’ straight

4504

4500

2’ straight

4505

4501

3’ straight

4506

4502

1’ 3” – 2’ 1”
(telescopic) 4542

3’ 4” – 4’ 6”
(telescopic) 4540

Tee piece with
end cap

4516

5” 127mm

19

3/

8

493mm

11

1/2

” 294mm

6

7/

8

1

75m

m

11

1/2

” 294mm

3

1/2

90mm

19” 481mm

2

3

5

/8

600

mm

Flue pipe connects your stove to the existing/new chimney system. The chimney system must meet the requirements of Building Regulations

(Document J) and the stove fitted in accordance with the detailed installation instructions provided with each unit. You may also download these

instructions prior to purchase from www.stovax.com.