Qualification form – Garmin PAV80 User Manual
Page 36
PS Engineering
PAV80
Installation and Operator’s Manual
200-800-0101
Appendix E
Rev. 5 Feb. 2004
Appendix E RTCA DO160D/EUROCAE ED-14D Enviro
nmental
Qualification Form
Part Number: 050-800-(-xxx)
Manufacturer: PS Engineering Incorporated 9800 Martel Road
Lenoir City TN 37772
Conditions Section
Conducted
Tests
Temperature and Altitude
Low Temperature
High Temperature
In-flight Loss of Cooling
Altitude
Decompression
Overpressure
4.0
4.5.1
4.5.2
4.5.4
4.6.1
4.6.2
4.6.3
Equipment tested to CAT B1
-55° C Storage, -20°C Low Operating
+85°C Storage, +50°C High Operating
Not Applicable, no cooling required
25,000’ unpressurized
Not Applicable
Not Applicable
Temperature variation
5.2
Equipment tested to Category C
Humidity
6.0
Equipment tested to Category A
Shock
7.0
Equipment tested to Operational test only
Operational 7.2
Crash Safety
7.3
Equipment tested Category B
Vibration
8.0
Equipment tested to Category S
Explosion
9.0
Category X, not tested
Waterproofness
10.0
Category X, not tested
Fluids Susceptibility
11.0
Category X, not tested
Sand and Dust
12.0
Category X, not tested
Fungus
13.0
Category X, not tested
Salt Spray
14.0
Category X, not tested
Magnetic Effect
15.0
Equipment tested to Category Z
Power input
16.0
Equipment tested to Category B
Voltage Spike
17.0
Equipment tested to Category B
Audio Frequency Susceptibil-
ity
18.0
Equipment tested to Category B
Induced Frequency Suscepti-
bility
19.0
Category X, not tested
Radio Frequency Susceptibil-
ity
20.0
Category X, not tested
Radio Frequency Emission
21.0
Equipment tested to Category H
Lightning Induced Transient
Susceptibility
22.0
Category X not tested
Lightning Direct Effects
23.0
Category X not tested
Icing
24.0
Category X, not tested
Electrostatic Discharge
25.0
Category X, not tested
Other Tests
Passed FM Emissions testing in accordance
with CFR 47, Part 15.109.