beautypg.com

Qualification form – Garmin PAV80 User Manual

Page 36

background image

PS Engineering

PAV80

Installation and Operator’s Manual

200-800-0101

Appendix E

Rev. 5 Feb. 2004

Appendix E RTCA DO160D/EUROCAE ED-14D Enviro

nmental

Qualification Form

Part Number: 050-800-(-xxx)

Manufacturer: PS Engineering Incorporated 9800 Martel Road

Lenoir City TN 37772

Conditions Section

Conducted

Tests

Temperature and Altitude
Low Temperature
High Temperature
In-flight Loss of Cooling
Altitude
Decompression
Overpressure

4.0
4.5.1
4.5.2
4.5.4
4.6.1
4.6.2
4.6.3

Equipment tested to CAT B1
-55° C Storage, -20°C Low Operating
+85°C Storage, +50°C High Operating
Not Applicable, no cooling required
25,000’ unpressurized
Not Applicable
Not Applicable

Temperature variation

5.2

Equipment tested to Category C

Humidity

6.0

Equipment tested to Category A

Shock

7.0

Equipment tested to Operational test only

Operational 7.2
Crash Safety

7.3

Equipment tested Category B

Vibration

8.0

Equipment tested to Category S

Explosion

9.0

Category X, not tested

Waterproofness

10.0

Category X, not tested

Fluids Susceptibility

11.0

Category X, not tested

Sand and Dust

12.0

Category X, not tested

Fungus

13.0

Category X, not tested

Salt Spray

14.0

Category X, not tested

Magnetic Effect

15.0

Equipment tested to Category Z

Power input

16.0

Equipment tested to Category B

Voltage Spike

17.0

Equipment tested to Category B

Audio Frequency Susceptibil-
ity

18.0

Equipment tested to Category B

Induced Frequency Suscepti-
bility

19.0

Category X, not tested

Radio Frequency Susceptibil-
ity

20.0

Category X, not tested

Radio Frequency Emission

21.0

Equipment tested to Category H

Lightning Induced Transient
Susceptibility

22.0

Category X not tested

Lightning Direct Effects

23.0

Category X not tested

Icing

24.0

Category X, not tested

Electrostatic Discharge

25.0

Category X, not tested

Other Tests

Passed FM Emissions testing in accordance
with CFR 47, Part 15.109.