Design Guide
CAUTION:
Under side edges
of the stainless
steel canopy top
may be sharp.
Wear heavy-duty
work gloves when
moving the top.
(A)
(B)
(C)
PREPARATION FOR BUILT-IN
UNDER-COUNTER INSTALLATIONS ONLY
The top canopy may be removed when installing under
a countertop.
• Remove the three screws from the back of the top
canopy (A).
• Using heavy-duty work gloves, lift up on the top canopy
back (B) and slide it forward until it unlatches from the
unit (C).
• Lift the top canopy up and off of the unit.
NOTE: Keep the top canopy and screws for future
free-standing installations.
NOTE: When installing the unit in a free-standing
configuration, the top canopy must be left in place.
• If replacing the top canopy make sure the three latches
in the front slide into the front lip of the canopy before
pushing the canopy to the rear of the unit.
PRODUCT CLEARANCES AND
LOCATION REQUIREMENTS
The Outdoor/Indoor Refrigerator is factory set for
a 110
° door swing.
When installed in a corner:
• Allow 5-1/4
″ min. clearance on the hinge side for
the 90
° door swing and to allow racks to slide out.
• Allow 15
″ minimum clearance on the hinge side for
a full 110
° door swing.
• Test the door swing. Carefully open and close the door.
Adjust if the door makes contact with cabinetry.
15" Minimum
to Wall
110
°
110
°
Door
Swing
21-5/8"
23-5/8"
5-1/4" Minimum
to Wall
90
°
90
°
Door
Swing
THE INSTALLATION SPACE
Free-Standing – Use canopy top Built-In – Remove canopy top
(if needed)
NOTE:
Handle and
handle standoff
depth is 2-3/4
″
36"
23-3/4"
23-3/4"
23-3/4"
34-1/4"
23-3/4"
to 34-3/4"
Choose the location:
• This product has been designed as a free-standing unit;
however, if desired, it may also be built-in.
• These products may be closed in on the top and
three sides as long as the front is unobstructed for
air circulation and proper access to the door.
• Do not operate these products where the temperature
will go below 45
°F (7°C) or above 120°F (49°C).
• Unit must be installed on a structurally sound and
level surface strong enough to support a fully loaded
refrigerator, or approx. 250 lbs.
Locate
Outlet
34-1/2" Min.
24"
23-3/4" Min.
1-1/2"
9"
Max.
10-1/2"
The cutout depth should be 24
″
The cutout dimensions shown allow for a full door
swing and access to the pull-out racks when installed
in standard 24
″ deep cabinets.
• The Outdoor/Indoor Refrigerator can be used
free-standing.
• If installing between frameless cabinets, a 1/2
″ wide
filler strip or side panel may be required on the hinge
side. The filler strip will act as a spacer between the
case and adjacent cabinet door swing. The width of
the opening must include the filler panels.
NOTE: In a standard 24
″ opening, the door will protrude
1-1/2
″ forward of the surrounding cabinets.
Additional Specifications
• A 120 volt 60Hz., 15 or 20 amp power supply is
required. An individual properly grounded branch
circuit or circuit breaker is recommended. Install
a properly grounded 3-prong electrical receptacle
recessed into the back wall as shown. Electrical
must be located on rear wall as shown. THIS PRODUCT
MUST BE CONNECTED TO A POWER SOURCE WITH
GROUND FAULT CIRCUIT INTERRUPTER (GFCI)
PROTECTION WHEN INSTALLED IN AN OUTDOOR
LOCATION. LOCAL CODES MAY REQUIRE A SEPARATE
CIRCUIT.