8 PNEG-301 Two-Ring Door
1. Installation
Inner Door Auger Hood (Optional)
12' (3.66 m) - 24' (7.32 m) Diameters Only
Figure 1C
Remove bolts, lock washers and nuts along each side of large square opening. Position auger shield as
shown in
and bolt to underside of top angle with bolt heads under shield. Replace bolts, lock
washers and nuts along sides of opening.
Bin Step (Optional)
Figure 1D
Unloading grain through door opening may cause grain bin failure if not done
properly. Unloading directly through the door opening should be limited to grain
bins no larger than 24' (7.32 m) diameter and grain depths no greater than
18' (5.49 m).
Unloading from the door opening should be done only with use of an auger
hood with the auger inserted through the opening to the center of the grain bin.