14

Maintenance

This product has been designed to be a low-maintenance tool. However, in order

to maintain its performance, you must

ALWAYS

follow these simple directions.

1.

ALWAYS

handle the tool with care. Treat it as you would any optical

device, such as a camera or binoculars.

2.

AVOID

exposing the self leveling vertical line generator to shock,

continuous vibration or extreme hot or cold temperatures.

3.

ALWAYS

store the self leveling vertical line generator indoors. When

not in use,

ALWAYS

store the self leveling vertical line generator in its

protective case.

4. When you are finished using the tool,

ALWAYS

make sure that the switch

is in “0” position.

5.

ALWAYS

keep the product free of dust and liquids. Use a damp cloth and

mild soap to clean the tool. If needed,

ONLY USE

a soft cloth or cotton

swab and glass cleaner to clean the lens.

WARNING: ALWAYS

remove the batteries when cleaning lens.

6.

ALWAYS

clean and thoroughly dry the tool after each use.

7. Check the batteries regularly to avoid deterioration.

ALWAYS

remove

the batteries from the tool, if it is not going to be used for an extended

period of time.

8. Replace the batteries after approximately 40 hours of use.
9.

DO NOT

disassemble the self leveling vertical line generator.. This will not

only void the warranty, but could expose the user to hazardous radiation

exposure.

10.

DO NOT

modify the tool in any way or use the tool with

products and/or accessories not specified in this instruction manual, this

could expose the user to hazardous laser radiation exposure.

11.

DO NOT

attempt to change any part of the laser lens.

NOTE:

This tool is not to be tampered with and should only be repaired by

a qualified Service Technician with laser experience.

Troubleshooting

Problem

Possible cause

Solution

Laser line

projection is

weak.

Batteries are weak.

Replace with fresh batteries.

Laser line is

hard to see

Light in area is too

bright.

Use laser enhancing glasses.

Batteries are weak.

Replace with fresh batteries.

Laser light is

not projected.

Power switch is not

“on”

Check to be sure the power

switch has been pushed

forward and is in the “1”

position.

Laser line

projected is

not upright.

The tool is not placed

on a horizontal surface

or the declining angle

of it is beyond ±3°.

Replace the tool on a

horizontal surface and make

sure the laser line can sway

after the tool is turned on.