Generator drive – GE Gas Turbine User Manual
Page 28
Generator Drive
(ISO conditions - natural gas - electrical generator terminals)
ISO RATED
HEAT RATE
EFFIC.
PRESSURE
EXHAUST
TURBINE EXHAUST
POWER
RATIO
FLOW
SPEED
TEMPERATURE
kW
kJ/kWh
%
kg/sec
Ibs/sec
RPM
°C
°F
PGT5
5,220
13,422
26.8
9.1
24.6
54.2
10,290
523
973
GE5
5,500
11,740
30.7
14.8
19.6 43.1
16,630
574
1,065
PGT10
10,220
11,540
31.2
13.8
42.3 93.3
7,900
488
910
GE10
11,250
11,481
31.4
15.5
47.5
104.7
11,000
482
900
PGT16
13,720
10,300
35.0
20.2
47.3
104.3
7,900
491
919
PGT20
17,464
10,238
35.2
15.7
62.5
137.7
6,500
475
887
PGT25
22,417
9,919
36.3
17.9
68.9 151.9
6,500
525
976
PGT25+
30,226
9,084
39.6
21.6
84.3
185.9
6,100
500
931
LM6000
42,703
8,770
41.0
27.9
125.8
288.8
3,600
452
840
MS5001
26,830
12,687
28.4
10.5
125.2
276.1
5,094
483
901
MS5002E
31,100
10,285
35.0
17.0
102.0
225.0
5,714
511
952
MS6001B
42,100
11,230
32.1
12.2
141.1
311.0
5,163
548 1,026
MS7001EA
85,400
10,990
32.7
12.6
292.0
643.0
3,600
537
998
MS9001E
126,100
10,650
33.8
12.6
418.0
921.0
3,000
543
1,009
28
GE Energy
Gas Turbines