220v operation – Grizzly G0640X User Manual
Page 11

G0640X 17" Wood/Metal Bandsaw
-9-
SECTION 2: CIRCUIT REQUIREMENTS
220V Operation
Full Load Amperage Draw
This machine draws the following amps under 
maximum load:
Amp Draw ................................................8 Amps
Power Supply Circuit Requirements
You MUST connect your machine to a grounded 
circuit that is rated for the amperage given below. 
Never replace a circuit breaker on an existing cir-
cuit with one of higher amperage without consult-
ing a qualified electrician to ensure compliance 
with wiring codes. 
If you are unsure about the
wiring codes in your area or you plan to con-
nect your machine to a shared circuit, consult
a qualified electrician.
Minimum Circuit Size .............................15 Amps
Extension Cords
Using extension cords may reduce the life of the 
motor. Instead, place the machine near a power 
source. If you must use an extension cord:
•
Use at least a 14 gauge cord that does not 
exceed 50 feet in length!
•
The extension cord must also have a ground 
wire and plug pin.
•
A qualified electrician MUST size cords over 
50 feet long to prevent motor damage.
Figure 1. NEMA 6-15 plug and receptacle.
Serious personal injury could occur if you
connect the machine to power before com-
pleting the setup process. DO NOT connect
the machine to the power until instructed
later in this manual.
Electrocution or fire could
result if machine is not
grounded and installed in
compliance with electrical
codes. Compliance MUST
be verified by a qualified
electrician!
Power Connection Device
The type of plug required to connect your machine 
to power depends on the type of service you cur-
rently have or plan to install. We recommend 
using the plug shown in 
Figure 1.