beautypg.com

7 gas conversion procedures (cont.) – Frymaster 24G Series User Manual

Page 28

background image

24G SERIES FLATBOTTOM GAS FRYERS

CHAPTER 3: INSTALLATION INSTRUCTIONS

3-13

3.7 Gas Conversion Procedures (cont.)


NON-CE UNITS ONLY:

See gas valve illustration below for reference when performing gas valve conversions.

When converting from natural gas to propane (or vice-versa), the following procedures apply:

Burner orifices and pilot orifice MUST be replaced (see page 3-11 for required component
part numbers).

Adjust orifice gas pressure by turning the gas-valve adjustment screw (see page 3-11 for gas
types and pressures).

After adjustment, replace the adjustment-screw cover.

Factory MUST be notified so the conversion can be documented and a new rating plate can
be sent out.


Conversion from one gas family to another (i.e. changing from natural gas to propane) requires
special components. Obtain the necessary components using the tables on page 3-11.


Conversions can only be executed by qualified, factory-authorized personnel.


Pressure flow adjustment

(remove cover screw to access)

ON/OFF Gas

Knob

Pilot gas supply

connection.

Pilot pressure

adjustment (remove

cover screw to access)

ON Button- Pilot

Gas-Flow

OFF Button

Thermocouple

Connection

Vent Tube

Connection

Pilot pressure

adjustment


Non-CE gas valve (typical)

CE gas valve (typical)