24G SERIES FLATBOTTOM GAS FRYERS

CHAPTER 3: INSTALLATION INSTRUCTIONS

3-11

3.6 Gas Inputs (cont.)

Gas Type

Orifice Part Number*

Natural

Propane

810-2051
810-2317

* Orifice sizes are listed for altitudes of 2000 feet and less.


20 mm

Loosen this screw to
adjust burner damper
for optimum flame.

Natural (G20/G25) Gas: Maximum Opening
Propane/LP (G31) Gas: 15 mm Opening

Ensure orifice tip is approximately
20 mm from the upper damper slot.


WARNING

If gas odors are detected, the gas supply

MUST

MUST

MUST

MUST be shut off at the main shut-off valve, and

the local gas company or authorized service agency contacted for immediate service.


3.7 Gas Conversion Procedures

DANGER

This appliance was configured at the factory for a specific type of gas. Converting from one

gas type to another requires the installation of specific gas-conversion components.

Switching to a different type of gas without installing the proper conversion components

may result in fire or explosion. NEVER ATTACH THIS APPLIANCE TO A GAS SUPPLY FOR

WHICH IT IS NOT CONFIGURED!

Conversion of this appliance from one type of gas to another should only be performed by

qualified, licensed, and authorized installation or service personnel, as defined in Section 1.5

of this manual.


See page 3-13 for gas valve illustration when performing gas conversion procedures.

Burner Adjustments- 24G Series