beautypg.com

Fluke 63 User Manual

Page 6

background image

Professional technicians select the rugged Fluke

63, 66 or 68 IR thermometers for maintenance

diagnostics in demanding environments. The

durability, optical resolution, accuracy and

extended temperature ranges make the Fluke 63,

66 and 68 the maintenance technician’s preferred

choice for daily MRO tasks. For special surfaces

such as concrete tiles or lead, the Fluke 66 and 68

offer adjustable emissivity.

Fluke 63, 66 and 68

Model

Fluke 63

Fluke 66

Fluke 68

Temperature range

-32 to 535 ºC

-32 to 600 ºC

-32 to 760 ºC

(–25 to 999 ºF)

(–25 to 1100 ºF)

(–20 to 1400 ºF)

D:S (Distance to spot size)

12:1

30:1

50:1

at 90 % energy
Laser sighting

Single point, offset

Emissivity

Preset 0.95

Adjustable

Accuracy

(Assumes ambient

± 1 % of reading or ± 1 ºC (± 2 ºF), (whichever is greater over the balance of the range)

operating temperature

of 23 ºC [73 ºF])
Response time

500 mSec

MAX, MIN, DIF and AVG
temperatures

MAX only

All

Recall last reading

HI/LO alarm

Protective hard case

Weight and dimensions

320 g (11 oz) and 200 x 160 x 55 mm (8 x 6 x 2 in)

Power

9 V alkaline

Battery life (alkaline)

20 hours with laser and backlight on 50% (Fluke 63) 40 hours with laser and backlight off (Fluke 66/68)

Display hold

7 seconds

LCD backlit

Warranty

2 years, conditional

This manual is related to the following products: