Model

Fluke 62 Mini

Temperature range

-30 to 500 ºC (–20 to 932 ºF)

D:S (Distance to spot size) at 80 % energy

10:1

Laser sighting

Single point, offset

Emissivity

Preset 0.95

Accuracy

± 1 ºC (2 ºF) from 10 ºC to 30 ºC (50 ºF to 86 ºF),

(Assumes ambient operating temperature of 23 ºC [73 ºF])

± 1.5 % of reading or ± 1.5 ºC (3 ºF)

(whichever is greater over the balance of the range)

Response time

500 mSec

Nylon holster

Weight and dimensions

200 g (7 oz) and 152 x 101 x 38 mm (6 x 4 x 1.5 in)

Power

9 V alkaline or NiCD battery

Battery life (alkaline)

12 hours

Display hold

7 seconds

LCD backlit

Warranty

2 years, conditional

Fluke 62 Mini

For quick, basic temperature checks in applications

where the technician is close to the target, there’s

nothing simpler than using a Fluke 62 Mini—just aim

the laser sighting at the center of your target, pull the

trigger, and read the temperature on the large, backlit

LCD. Rugged enough for industrial environments with

its protective rubber “boot”, the 62 Mini also comes

with a handy storage pouch that can be snapped to

your belt, keeping quick temperature checks at your

fi ngertips.