Maintenance, 1 adjustment, 2 line voltage check – Furuno Satellite Compass SC-50/110 User Manual
Page 16: 3 jumper setting, 4 led

12
6. Maintenance
6.1 Adjustment
1) PWR board
Switching regulator frequency is adjusted on PWR board, 20P8181 as below.
Test Point
GND
Rating
Adjuster
TP2
TP1
120.0 kHz ±
10 kHz
VR79
TP5
TP3
120.0 kHz ± 10 kHz
VR80
2) MAIN board
Vcc-c supply voltage to Rate sensor is adjusted by VR96 on MAIN board, 20P8178.
Test Point
GND
Rating
Adjuster
#1 of J20
#2 of J20
5.0 V (Vcc-c)
VR96
6.2 Line voltage check
Line voltages are checked at J3 on the MAIN board.
Line voltage
Test Points on MAIN board
Rating
3.3 V
#4 (+) and #5(-) of J3
3.15 to 3.45 V
5.1 V (5 V)
#1 (+) and #5(-) of J3
4.94 to 5.46 V
6.5 V
#8 (+) and #5(-) of J3
6.2 to 6.8 V
13.5 V (15 V)
#7 (+) and #5(-) of J3
12.5 to 14.4 V
6.3 Jumper setting
Jumper JP1 on the MAIN board is used at factory to set the MAIN board to A or B version.
6.4 LED
CR3 on the MAIN board blinks when the CPU is running.
- FAR-2805 Series (169 pages)
- FR-8062 (2 pages)
- FR-8122 (56 pages)
- CH-37 (90 pages)
- CH-37 (71 pages)
- FAR-2XX7 (4 pages)
- FAR-2XX7 (2 pages)
- FELCOM16 (4 pages)
- FRS-1000B (8 pages)
- FRS1000 (8 pages)
- Ls4100 (48 pages)
- 520 (73 pages)
- Marine Radar (24 pages)
- 1944C-BB (233 pages)
- 1733C (260 pages)
- FR-2105 (197 pages)
- FMD-8010 (50 pages)
- GD-1900C (260 pages)
- Black Box Video Sounder FCV-1200BB (2 pages)
- FR-1505 MARK-3 (4 pages)
- 1762 (252 pages)
- NAVnet DRS12A (44 pages)
- FAR-2127 (136 pages)
- FAR-2137S (8 pages)
- FA30 (6 pages)
- 1715 (48 pages)
- 1715 (2 pages)
- 1734C (55 pages)
- GD-1720C (53 pages)
- Mu 120c (2 pages)
- NAVNET GD-1920C (239 pages)
- CI-80 (41 pages)
- FAR-28x7 Series (299 pages)
- FAR-2837S (8 pages)
- BBWX1 (2 pages)
- 851 MARK-2 (37 pages)
- 851 MARK-2 (47 pages)
- BBFF3 (1 page)
- CSH-53 (106 pages)
- CSH-53 (108 pages)
- FCV295 (53 pages)
- FR1500 Mk3 (79 pages)
- FI-50 Series (2 pages)
- FCV-1150 (32 pages)