4.1 Mounting Requirements

C141-E230

4-5

(6) Environmental

temperature

Temperature condition at installed in a cabinet is indicated with ambient temperature measured
30 mm from the disk drive. At designing the system cabinet, consider following points.

• Make a suitable air flow so that the DE surface temperature never exceed 60°C.

• Cool the PCA side especially with air circulation inside the cabinet. Confirm the cooling effect

by measuring the surface temperature of specific ICs and the DE. These measurement results
must satisfy the temperature condition listed in Table 4.1.

• Keeping the DE surface temperature at 50°C or below at ambient temperature 30°C, which is a

condition for assuring an MTBF of 1,400,000 hours, requires an air flow of 0.5 m/s or more.

Table 4.1

Surface temperature check point and maximum temperature

No.

Measurement point

Maximum temperature

1 DE

Surface

60°C

2

Read channel LSI

80°C

3 VCM/SPM

Driver

93°C

4 HDC

92°C

5 MPU

90°C



Figure 4.5 Surface temperature measurement points