Pre operation leak testing – FRIGIDAIRE Outdoor Grill with Electronic Ignition User Manual
Page 11
GENERAL INFORMATION
Although all gas connections on the grill are leak tested prior to shipment, a complete gas tightness check must be per-
formed at the installation site due to possible shifting during shipment, installation or excessive pressure unknowingly
being applied to the unit. Periodically check the whole system for leaks and immediately check the system if the smell
of gas is detected.
BEFORE TESTING
Do not smoke while leak testing. Extinguish all open flames. Never leak test with an open flame.
Mix a solution of equal parts mild detergent or liquid soap and water.
TESTING
1. Turn off the burner control knobs.
2. Turn the top knob of the fuel supply cylinder counterclockwise (right to left) two (2) rotations to open.
3. Apply the soap solution to connections of the fuel supply assembly. If no soap bubbles appear, there is no gas leak. If
bubbles form at the connections, a leak is detected. If a leak is detected, immediately turn off the gas supply, tighten
any leaking fittings, turn gas on, and repeat steps 1-3.
4. Turn off the knob on the fuel supply cylinder.
5. Turn on the burner control knobs for a moment to release the pressure in the hose, then turn the control knobs back off.
6. Wash off soapy solution with cold water and towel dry.
Check all gas supply fittings before each use and each time the gas supply cylinder is connected to the regulator.
Have a qualified service technician leak test the grill any time a part of the gas system is replaced.
Also it is recommended to perform a leak test at least once a year whether or not the L.P. gas supply cylinder has been
disconnected.
NOTE: When leak testing this appliance, make sure to test and tighten all loose connections, including the side burner.
A slight leak in the system can result in a low flame, or hazardous condition. Most L.P. gas tanks now come equipped
with a leak detector mechanism internal to the tank, when gas is allowed to escape rapidly it shuts off the gas
supply. A leak may significantly reduce the gas flow making the grill difficult to light or causing low flames.
NOTE: If you cannot stop a gas leak turn off the gas supply and call your local gas company or the dealer you
purchased the appliance from. If necessary, replace the faulty part with the manufacturer’s recommended
replacement part. A slight leak could cause a fire.
11
Pre Operation Leak Testing