Current Requirements and Power Dissipation
Table 1.3 lists the current and power dissipation.
Table 1.3
Current and power dissipation
Typical RMS current (*1) [mA]
+12 V
+5 V
Model
MPE
3102AH
MPE
3136AH
MPE
3204AH
MPE
3273AH
All
Models
MPE
3102AH
MPE
3136AH
MPE
3204AH
MPE
3273AH
Spin up
1600
1800 peak
1600
1800 peak
1600
1800 peak
1600
1800 peak
540
640 peak
21.9
21.9
21.9
21.9
Idle (Ready)
(*3)
340
340
400
460
420
6.2
6.2
6.9
7.6
R/W (On Track)
(*4)
340
340
400
460
450
6.3
6.3
7.1
7.8
Seek (Random)
(*5)
640
640
670
700
420
9.8
9.8
10.1
10.5
Standby
7.0
7.0
7.0
7.0
185
1.0
1.0
1.0
1.0
Sleep
7.0
7.0
7.0
7.0
185
1.0
1.0
1.0
1.0
*1
Current is typical rms except for spin up.
*2
Power requirements reflect nominal values for +12V and +5V power.
*3
Idle mode is in effect when the drive is not reading, writing, seeking, or executing any commands. A portion of the R/W circuitry is powered
down, the spindle motor is up to speed and the Drive ready condition exists.
*4
R/W mode is defined as 50% read operations and 50% write operations on a single physical track.
*5
Seek mode is defined as continuous random seek operations with minimum controller delay.
Typical Power (*2) [watts]