Furuno SC-60 User Manual
Page 35
2. INSTALLATION
2-21
2.6.3
Heading data format
1. Turn off the processor unit.
2. Unfasten four screws from the processor unit to remove the top cover.
3. Choose the heading format of the equipment connected to the ports HDG
OUT 1, HDG OUT 2 and HDG OUT 3 with the jumper wires on the circuit
board 20P8171, referring to the table below. The default setting for each port
is AD-10.
Jumper wire and format on the circuit board 20P8171
Port Format
Setting
Remarks
AD-10
J11 < - > J13
HDG OUT 1
NMEA
J11 < - > J12
AD-10
J14 < - > J16
HDG OUT 2
NMEA
J14 < - > J15
AD-10
J17 < - > J19
HDG OUT 3
NMEA
J 17 < - > J18
NMEA and AD-10 are identified
on the circuit board. Choose
NMEA for IEC 61162-1
sentences.
BEA
CON
HEAD1
ANGULAR
RATE SENSOR
HEAD2
HEAD3
NMEA
(IEC 61162)
NMEA (IEC 61162)
NMEA (IEC 61162)
AD-10
AD-10
AD-10
20P8171
Processor unit, cover opened, top view