Furuno SC-60 User Manual
Page 22
2. INSTALLATION
2-8
4. The DGPS antenna is supplied with a 15 m cable. If extension is necessary,
use the extension cable (option). Cover the extension connector with
vulcanizing tape and vinyl tape, for waterproofing. Tie tape ends with a cable
tie.
Extension Cable: Type: OP08-15-30, Code No.: 004-396-440 (30 m)
Type: OP08-15-60, Code No.: 004-396-450 (60 m)
Name Type Code
No.
Qty
Remarks
Connector TNC-SA-JJ
000-139-113 1
TNC-PS-3D L30M 000-139-078
30 m, connector at
both ends
Cable
TNC-PS-3D L60M 000-139-080
1
60 m, connector at
both ends
Waterproofing the extension connector
For cable RG-10UY (local supply, max. length 60 m), use the optional antenna
cable set.
Antenna cable set Type: OP08-17, Code No.: 004-392-510
Name Type
Code
No.
Qty
Remarks
Converter Cable Assy.
NJ-TP-3DXV-1
000-123-809
2
Connector TNC-SA-JJ
000-139-113
1
Connector N-P-7
000-501-514
2
*N-P-7
Processor
Unit
* Converter cable assy. (supplied with antenna cable set)
*TNC-SA-JJ
15 m
RG-10UY
Cable connection when using cable RG-10UY