Venting installation – FMI (V)S36 User Manual
Page 9
www.fmiproducts.com
111026-01G
9
Venting installatiOn
Continued
14
3
/
8
"
(36.5 cm)
30"
(76.2 cm)
1"
(2.5
cm)
1"
(2.5
cm)
Minimum Measurements
1"
(2.5 cm)
Opening "A"
Pitch
Slope Opening "A"
Max.
Used Flashing
Model No.
Flat
0°
15"
V6F-8DM
0-6/12
26.6°
16
1
/
8
"
V6F-8DM
6/12-
12/12
45.0°
20
3
/
8
"
V12F-8DM
FLASHING INSTALLATION (V6F-8DM
OR V12F-8DM)
Determine the flashing to be used with the roof
opening chart. Slide flashing over pipe until
base is flat against roof. Replace as many
shingles as needed to cover exposed area
and flashing base. Secure in position by nail-
ing through shingles (see Figure 13). DO NOT
NAIL THROUGH FLASHING CONE.
Installing Flashing on a Metal Roof
When installing flashing on a metal roof, it is
required that putty tape be used between the
flashing and roof. The flashing must be secured
to the roof using #8 x 3/4" screws and then
sealed with roof coating to prevent leakage
through screw holes. A roof coating must also be
applied around perimeter of flashing to provide
a proper seal.
Figure 12 - Roof Opening Measurements
Nail Only
Outer
Perimeter
of Flashing
Storm Collar
Flashing
Cone
Underlap Shingles
at Bottom
Overlap
Shingles Top
and Sides Only
Figure 13 - Flashing Installation
Storm Collar Installation (SC1 or SC2)
Place storm collar over pipe and slide down
until it is snug against the open edge of the
flashing (see Figure 14). Use SC1 for all round
terminations and SC2 for all terminations with
slip sections. Apply waterproof caulk around the
perimeter of the collar to provide a proper seal.
Figure 14 - Storm Collar
Chimney
Pipe
Waterproof
Caulk
Storm
Collar
Flashing
Terminations/Spark Arrestor
The fireplace system must be terminated with
the listed round top or chase terminations. In
any case, refer to the installation instructions
supplied with the termination. The termination
approved for this fireplace are the RT-8DM and
RTL-8DM that can be used for flashing or chase
and ET-8DM, ETO-8DM, ETL-8DM and ETLO-
8DM for chase style termination only. Figure 15
shows an RTL-8DM round top termination.
CAUTION: Do not seal open-
ings on the rooftop flashing. Fol-
low the installation instructions
provided with the termination
being used.
Attach Bracket
Tabs to
Outer Pipe
(3 Places)
Secure with
Screws
RTL-8D
Level of
Flue Gas
Outlet
Caulk
Collar
Flashing
Underlap
Shingles
Bottom Only
Figure 15 - Termination
Overlap
Shingles Top
and Sides