(4)
Current fluctuation (Typ.) when power is turned on
Note:
Maximum current is 1.5 A and is continuance is 1.5 seconds
Figure 1.1
Current fluctuation (Typ.) when power is turned on
(5)
Power on/off sequence
The voltage detector circuit monitors +5 V and +12 V. The circuit does not allow a write
signal if either voltage is abnormal. This prevents data from being destroyed and eliminates