beautypg.com

Notice, Warning, Routine maintenance – Friedrich HAZARDGARG R-410A User Manual

Page 22

background image

ROUTINe MAINTeNANCe

AIR FILTER

Clean the unit air intake filter at least every 300 to 350 hours

of operation. Clean the filters with a mild detergent in warm

water and allow to dry thoroughly before reinstalling.

COILS AND BASE PAN

The indoor coil (evaporator coil), the outdoor coil (condenser

coil) and base pan should be inspected periodically

(yearly or bi-yearly) and cleaned of all debris (lint, dirt,

leaves, paper, etc.). Clean the coils and base pan with a soft

brush and compressed air or vacuum. If using a pressure

washer, be careful not to bend the aluminium fin pack. Use

a sweeping up and down motion in the direction of the verti-

cal aluminum fin pack when pressure cleaning coils. Cover

all electrical components to protect them from water or spray.

Allow the unit to dry thoroughly before reinstalling it in the

sleeve.

BLOWER WHEEL / HOUSING / CONDENSER FAN /

SHROUD

Inspect the indoor blower housing, evaporator blade, con-

denser fan blade and condenser shroud periodically (yearly

or bi-yearly) and clean of all debris (lint, dirt, mold, fungus,

etc.). Clean the blower housing area and blower wheel with

an antibacterial / antifungal cleaner. Use a biodegradable

cleaning agent and degreaser on condenser fan and con-

denser shroud. Use warm or cold water when rinsing these

items. Allow all items to dry thoroughly before reinstalling

them.

ELECTRONIC / ELECTRICAL / MECHANICAL

Periodically (at least yearly or bi-yearly): inspect all control

components: electronic, electrical and mechanical, as well as

the power supply. Use proper testing instruments (voltmeter,

ohmmeter, ammeter, wattmeter, etc.) to perform electrical

tests. Use an air conditioning or refrigeration thermometer

to check room, outdoor and coil operating temperatures.

Use an electronic tester to measure wet bulb temperatures

indoors and outdoors.

Units are to be inspected and serviced by qualified service

personnel only. Use proper protection on surrounding

property. Failure to follow this notice could result in

moderate or serious property damage.

NOTICE

EXCESSIVE WEIGHT HAZARD

WARNING

Use two people to lift or carry the unit, and wear

proper protective clothing.

Failure to do so may result in personal injury.

Do not use a caustic coil cleaning agent on coils or base

pan. Use a biodegradable cleaning agent and degreaser,

to prevent damage to the coil and/or base pan.

NOTICE

ELECTRIC SHOCK HAZARD

WARNING

Turn off electric power before inspections,

maintenances, or service.

Extreme care must be used, if it becomes

necessary to work on equipment with power

applied.

Failure to do so could result in serious injury

or death.

CUT/SEVER HAZARD

WARNING

Be careful with the sharp edges and corners.

Wear protective clothing and gloves, etc.

Failure to do so could result in serious injury.

21