Window installation – Fedders AEY08F2B User Manual
Page 4
Carpenter’s level
Window sash
Filler panel
5/8” wood screw
Window sill
WINDOW INSTALLATON
INSTALLATION
4
1.
Open window, by raising lower window sash, and mark
the center of window sill. Carefully place cabinet in
window and align center hole on the bottom bar with the
center mark on the window sill.
2.
Close lower window sash until it touches behind the top
bar. (Do not release your grip on the cabinet until the
lower window sash is in its final position).
3.
Attach the cabinet to the window sill by driving one 1” long
wood screw through the bottom bar into the window sill.
Be sure cabinet maintains an downward pitch. Air
conditioner should slant slightly downward on the
outside as shown by 1/2 a bubble off on a carpenter’s
level. This outward pitch prevents water from entering the
room.
Securing the Filler Panels
1.
Slide filler panels outward until they touch window sash
tracks.
2.
Secure top of filler panels by driving a 5/8” wood screw
through each top mounting hole into window sash.
3.
Secure bottom of filler panels by driving a 5/8” wood
screw into window sill through each filler panel tab.
4.
Install chassis into cabinet.
Installing the Chassis into the Cabinet
1.
Slide the chassis into the cabinet.
2.
Replace the two anti-theft screws at the bottom front sides
of cabinet.
3.
To replace the decorative front, line up the top tabs and
sides, and gently press into position. Reattach the screws
on both sides of the decorative front. Make sure the
power cord aligns with the power cord slot on the bottom
of the decorative front. Make sure the decorative front is
secure before reconnecting the plug and operating the
unit.
4.
Cut plastic foam seal to width of window and install
between upper and lower window sash.
5.
Use latex or silicone sealant (not supplied) to fill any
minor openings.
Window sill
Bottom bar
1” Wood screw
A
B
C
D
D
E
E
Foam seal
Lower sash
Filler panel
Molding
Window Sill
Anti-theft screw
Chassis
Dec front
A
D
C
B
E
H
G
F
A
A
B
B
C
C
A
B
C
D
E
F
G
H
A
D
C
B
Do not drill a hole in the bottom pan. Unit is
designed to operate with approximately 1/2” of
water in bottom pan.
Do not obstruct the air intake area of your air conditioner,
as this could cause overheating, thus activating the unit’s
security switch and shutting off the unit. Do not block
aiflow inside with blinds, curtains, or furniture. Do not
block airflow outside with shrubs, enclosures, or other
buildings.
Side view
Window Installation
(cont.)