beautypg.com

Important grounding requirements, Recommended wire sizes – Fedders AEY08F2B User Manual

Page 2

background image

2

ELECTRICAL REQUIREMENTS

& SAFETY PRECAUTIONS

IMPORTANT

WARNING

WARNING

Do not remove or modify this plug
Do not use as an on/off switch
Do not use outdoors
Do not push furniture against or place

furniture on the electrical cord. This can trip
the test switch and/or damage the cord and
become a potential condition for arcing

Do not attempt to repair the cord. If the cord

requires replacement, call an authorized
servicer.

• The Arc Detection Device is not a Ground

Fault Interrupter and should not be used as
such

• The Arc Detection Device contains an

electronic circuit board and should not be
submerged or exposed to water spray

Resetting
If the Arc Detection Device has tripped, the
reset button will pop up.
Follow these steps to reset the Arc Detection
Device:
1. Unplug unit from electrical outlet
2. Press the reset button
3. Plug the unit back into electrical outlet
4. Check to see if power has returned to the

unit

Testing
You should test the Arc Detection Device
equipped power cord monthly, after every
major electrical storm, or if power to your
Room Air Conditioner has been interrupted.
Follow these steps to test the Arc Detection
Device:
1. Unplug unit from electrical outlet
2. Press the reset button
3. Plug the unit back into electrical outlet
4. Press test button. Unit should trip and reset

button will pop up.

5. Press reset button again for use

If above test fails, stop using the air
conditioner and contact customer service
by calling the following toll-free number:
1-800-332-6658
or email: [email protected]

Power Cord with
Arc Detection Device

The power cord supplied with this air
conditioner is equipped with an Arc
Detection Device designed to shut off power
to the unit when it senses an arc fault
condition. An arc fault is an unintentional
electrical discharge that occurs when
electrical products or wires are damaged,
aged, or improperly used. An arc fault can be
potentially hazardous if left undetected.

Electrical Shock Hazard

• Plug unit only into a grounded

electrical outlet.

• Do not use an extension cord or plug

adapter with this unit.

• Do not operate unit with decorative front

or filter removed.

• Failure to follow these precautions could

result in electrical shock, fire or personal
injury.

• If the air conditioner has a serial plate

rating of 115 volts and greater than 7.5
amps, it must have its own fuse or circuit
breaker, and no other device or unit
should be operated on that fuse or circuit
breaker.

• If the air conditioner has a serial plate

rating of 230 volts, it must have its own
fuse or circuit breaker, and no other
device or unit should be operated on that
fuse or circuit breaker.

• We recommend that a qualified

electrician install unit in accordance with
the National Electrical Code and local
codes and ordinances.

• Use copper conductors of correct wire

gauge and protector size only.

• Do not alter cord or plug end. Do not

remove warning label on cord.

Important Grounding Requirements

• Air conditioner has a three-prong

grounding plug on the power supply cord,
which must be plugged into a properly
grounded three-prong wall receptacle for
your protection against possible shock
hazard. For models up to and including
7.5 amperes, use a grounding type wall
receptacle to match the cord plug.

• For models above 7.5 amperes use a

single outlet grounding type wall
receptacle to match the cord plug.

Additional Safety Precautions

Do not cut, alter or remove any of the

expanded polystyrene (styrofoam)
inside this air conditioner.

Do not store or use gasoline or other

flammable vapors and liquids in the
vicinity of this or any other appliance.
The fumes can create a fire hazard or
explosion.

Do not introduce objects in the air

discharge area. This could cause
permanent damage.

Do not pour liquids on the air

conditioner as this could cause a
malfunction. With the unit unplugged,
use a damp cloth for cleaning the unit.

Do not use strong solvents to clean

the air conditioner.

• Clean the air conditioner filter every

two weeks to avoid overheating
caused by air obstruction. Do not
operate without filter.

Do not obstruct the air intake area of

your air conditioner, as this could
cause overheating, thus activating the
unit’s security switch and shutting off
the unit.

Do not block air circulation to outside

louvers of cabinet.

Do not block air flow inside with

blinds, curtains, or furniture, or
outside with shrubs, enclosures, or
other buildings.

Do not run the air conditioner with an

outside protective cover in place. This
could result in fire or mechanical
damage within the air conditioner.

250V

30A

250V

15A

125V

15A

250V

20A

Warning

Do not operate this air conditioner without
proper time delay circuit protection
(circuit breaker or fuse). Refer to serial
plate for proper power supply
requirements.

Recommended Wire Sizes

(As installed per building code) :
PROTECTOR SIZE

WIRE GAUGE

15 AMP #14 MINIMUM
20 AMP #12 MINIMUM
30 AMP #10 MINIMUM