TROUBLESHOOTING

ELECTRONIC IGNITION SYSTEM

Note: Before troubleshooting the system, make sure the gas shutoff valve is ON.
The two most common causes of a malfunctioning gas appliance are:
1. Loose wiring connections
2. Construction debris clogging the pilot and/or gas control valve filter

OBSERVED PROBLEM

Pilot will not light

Pilot will not stay lit

No gas to burner, although wall

switch and valve are set to the

ON position

Frequent pilot outage

Pilot goes out when wall switch

is ON

POSSIBLE CAUSE

1. No gas supply or shutoff

valve is OFF

2. Construction debris clog-

ging pilot orifice

3. Low gas pressure

4. Control valve knob is not on

the PILOT position

5. Kinked pilot line

6. Bad valve

1. Loose wiring on thermopile

to regulator valve. No mil-

livolt current is being sent

back to regulator

2. If valve knob and wall switch

are in the ON position, prob-

able defective control valve

1. Wall switch wires defective

2. Thermocouple generator or

sensor not generating suf-

ficient voltage

1. Pilot flame may be too

low, causing safety pilot to

“drop out”

1. Output on flame sensor too

high

REMEDY

1. Check to see if you have gas

supply

2. Remove debris and dirt, in-

spect and clean any other

possible obstructions

3. Contact your gas supplier

4. Refer to section on pilot

lighting

5. Have a qualified technician

replace pilot line

6. Replace control valve (see

Replacement Parts and Acces-

sories, page 19)

1. Check wiring connections.

Refer to wiring diagrams on

page 16

2. Have a qualified technician

replace valve (see Replace-

ment Parts and Accessories,

page 19)

1. Check electrical connections

and wires for continuity

2. See Pilot will not stay lit,

above

1. Clean and adjust pilot flame

for maximum flame impinge-

ment on thermopile

1. Replace flame sensor