beautypg.com

Operating fireplace – FMI GL36STEP User Manual

Page 14

background image

www.fmiproducts.com

55173H

14

TO TURN OFF GAS

TO APPLIANCE

1. Turn off the wall switch.
2. Turn off all electric power to the appliance

if service is to be performed.

3. Remove control access panel.
4. Push in gas control knob and turn clockwise

to “OFF”. Do not force.

5. Replace control access panel.

OPERATING FIREPLACE

Continued

Figure 24 - Pilot

Thermopile

Pilot

Burner

Ignitor

ELECTRONIC MODELS

FOR YOUR SAFETY

READ BEFORE LIGHTING

WARNING: If you do not fol-

low these instructions exactly,

a fire or explosion may result

causing property damage, per-

sonal injury or loss of life.

A. This appliance has a pilot which must be

lighted by hand. When lighting the pilot,

follow these instructions exactly.

B. BEFORE LIGHTING smell all around the

appliance area for gas. Be sure to smell next

to the floor because some gas is heavier than

air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.

• Do not touch any electric switch; do not

use any phone in your building.

• Immediately call your gas supplier from

a neighbor’s phone. Follow the gas sup-

plier’s instructions.

• If you cannot reach your gas supplier,

call the fire department.

C. Use only your hand to push in or turn the

gas control knob. Never use tools. If the

knob will not push in or turn by hand, don’t

try to repair it, call a qualified service tech-

nician or gas supplier. Force or attempted

repair may result in a fire or explosion.

D. Do not use this appliance if any part has

been under water. Immediately call a

qualified service technician to inspect the

appliance and to replace any part of the

control system and any gas control which

has been under water.

LIGHTING

INSTRUCTIONS

NOTICE: During initial operation

of new heater, burning logs will

give off a paper-burning smell.

Orange flame will also be pres-

ent. Open window to vent smell.

This will only last a few hours.

1. STOP! Read the safety information,

column 1.

2. Set the thermostat to lowest setting (if

applicable).

3. Turn off wall switch.
4. Open control access panel or louver.
5. Smell for gas, including near the floor. If you

smell gas, STOP! Follow “B” in the safety

information in column 1. If you don’t smell

gas, go to the next step.

6. Turn the main burner wall switch to the ON

position for ignition. There will be a spark

at the electrode.

7. Replace control access panel or louver once

there is a flame at the burner.

8. If burner will not stay lit after several tries,

flip the wall switch to OFF and call your

service technician or gas supplier.

Figure 25 - Electronic Control Valve

E

A

From

Gas

Supply

To

Main

Burner

Inlet

Pressure

Outlet

Pressure

This manual is related to the following products: