beautypg.com

Cleaning and maintenance, Operating fireplace, Technical service – FMI GL36STEP User Manual

Page 15: Specifications

background image

www.fmiproducts.com

55173H

15

CLEANING AND

MAINTENANCE

WARNING: Installation and

repair should be done by a

qualified service person. The

appliance should be inspected

before each use and at least

annually by a qualified service

person. More frequent clean-

ing may be required due to

excessive lint from carpeting,

bedding material, pet hair, etc.

It is imperative that the control

compartments, burners and

circulating air system be kept

clean.

WARNING: The logs can be

hot. Handle only when cool.

TO TURN OFF GAS

TO APPLIANCE

1. Turn off all electric power to the appliance

if service is to be performed.

2. Remove control access panel.
3. Close the gas valve.

OPERATING FIREPLACE

Continued

Figure 26 - Pilot

WARNING: Turn off gas and

electrical power before servicing

appliance. Any safety screen

or guard removed for servicing

must be replaced prior to operat-

ing the appliance.

WARNING: Failure to keep

the primary air opening(s) of

the burner(s) clean may result in

sooting and property damage.

Keep control compartment, logs, burner and area

surrounding logs clean by vacuuming or brushing

at least twice a year. Take care not to alter the set-

tings on the pilot assembly.
Do not use abrasive liquids or cleaners for cleaning

glass doors and trims. Any household glass cleaner

should suffice. Do not clean doors when hot. Allow

appliance to cool before cleaning.

TECHNICAL SERVICE

You may have further questions about installation,

operation or troubleshooting. If so, contact FMI

PRODUCTS, LLC’s Technical Service Depart-

ment at 1-866-328-4537. When calling please

have your model and serial numbers of your

heater ready.
You can also visit our web site at

www.fmiproducts.com.

SPECIFICATIONS

(V)GL36ST, (V)GL36STE

• Maximum Input Rating at Altitudes: 2,000 ft.

- 42,000 Btu/hr., 2,000 ft. to 4,000 ft. - 37,800

Btu/hr.

• Manifold Pressure: 3.5 W.C. (.87 kPa)
• Supply Pressure (in. of water): Minimum* - 4.5"

(1.12 kPa), Maximum - 11.0" (2.74 kPa)

• Orifice Size at Altitudes: 2,000 ft. - #30, 2,000 ft.

to 4,000 ft. - #31

(V)GL36STP, (V)GL36STEP

• Maximum Input Rating at Altitudes: 2,000 ft.

- 42,000 Btu/hr., 2,000 ft. to 4,000 ft. - 37,800

Btu/hr.

• Manifold Pressure: 11.0 W.C. (2.74 kPa)
• Supply Pressure (in. of water): Minimum* -

12.0" (2.89 kPa), Maximum - 13.0" (3.23 kPa)

• Orifice Size at Altitudes: 2,000 ft. - #49, 2,000 ft.

to 4,000 ft. - #51

* For the purpose of input adjustment

This manual is related to the following products: