beautypg.com

Furuno FR-7112 User Manual

Page 43

background image

SP - 3

Heading (Magnetic):

HDM>HDG

*1

>HDT

*1

>VHW>VHW

*1

Course (True):

RMC>RMA>VTG

Course (Magnetic):

VTG>RMC>RMA

Waypoint(Range, Bearing): RMB>BWC>BWR

Loran time difference:

RMA>GLC>GTD

Water depth:

DPT>DBT>DBK>DBS

Water temperature:

MTW>MDA

Time: ZDA

XTE: RMB>XTE>APB

*1: calculate by magnetic drift.

(7) Output Data

NMEA0183(Ver.1.5/2.0), RS-422

TLL (target data) and RSD

5. ENVIRONMENTAL CONDITION

(1) Ambient Temperature

Scanner Unit: -25°C to +70°C

Display Unit: -15°C to +55°C

(2) Relative Humidity

95 % or less at +40°C

(3) Waterproofing

Scanner Unit

IPX6

Display Unit

Chassis: not specified

Panel:

IPX4

6. POWER SUPPLY & POWER CONSUMPTION

(1) Power Supply

FR-7062/7112: 12/24/32 VDC (10.8 to 41.6 VDC)

FR-7252: 24/32 VDC (21.6 to 41.6 VDC)

(2) Voltage and Current

FR-7062

XN12A(24rpm): 12 VDC/7.5A, 24VDC/3.8A, 32VDC/2.8A

XN12A(48rpm): 12 VDC/8.8A, 24VDC/4.4A, 32VDC/3.3A

XN13A(24rpm): 12VDC/10A, 24VDC/5A, 32VDC/3.8A

FR-7112

XN12A(24rpm): 12 VDC/8.3A, 24VDC/4.2A, 32VDC/3.1A

XN12A(48rpm): 12 VDC/10A, 24VDC/5A, 32VDC/3.8A

XN13A(24rpm): 12 VDC/10.8A, 24VDC/5.4A, 32VDC/4.1A

FR-7252

XN12A(24rpm): 24VDC/5.2A, 32VDC/3.9A

XN12A(48rpm): 24VDC/5.8A, 32VDC/4.4A

XN13A(24rpm): 24VDC/6.3A, 32VDC/4.7A

(3) Power Consumption

FR-7062

XN12A(24rpm): 70 W to 90 W(100 kt)

XN12A(48rpm): 85 W to 105 W(70 kt)

This manual is related to the following products: