Dimensions and clearances

Entire front of icemaker must be clear of obstructions/connections to allow removal.

1" (26mm) clearance above icemaker for service.

1" (26mm) minimum clearance on sides.

The intake and exhaust air grilles must provide at least 150 sq in (968 sq cm) of open area.

Air-cooled model HCE1000A icemakers – 18" (458mm) minimum clearance between discharge and air
intake-grilles.

Front View

Side View

Back View

Air intake

PSIG

THE USA

MADE IN

OZ

PHASE

SINGLE

LOW SIDE

CHARGE

PART NO

R

R

HZ

Easton Pennsylvania

208264

AMPS

AMPS

VOLTS

SERIAL NO

CORPORATION

MODEL

Service No.

Product

Module No.

REFRIGERANT

FULL LOAD AMPS

Stock Module Identification Plate

DESIGN PRESSURE HIGH SIDE

MAX. BRANCH CIRCUIT FUSE SIZE

MIN. BRANCH CIRCUIT AMPACITY

MOTOR COMPRESSOR THERMALLY PROTECTED

C

NSF

U L

U L

Air exhaust

21.05" (535mm)

23.50"

(597mm)

21.28" (541mm)

Air exhaust
both sides

Ice transport hose connection

6.95"

(177mm)

3/4" MPT drain

3/8" OD push-in water inlet

23.77" (604mm)

15.56"

(396mm)

2.53"

(65mm)

2.43" (62mm)

1/4" FPT condensor drain
(water-cooled only)

1/4" FPT condensor inlet
(water-cooled only)

29.63" (753mm)

Cord only

CAUTION

• Keep ventilation openings in the appliance enclosure or built-in structure, clear of obstruction