beautypg.com

Specifications, Electrical, Caution – Follett HCE1000W User Manual

Page 5: Plumbing, Ambient, Heat rejection, Ice production

background image

5

Specifications

Electrical

Each icemaker requires its own separate circuit with electrical disconnect within 10 ft (6m).
Equipment ground required.
Standard electrical – 220-240/50/1
Maximum icemaker fuse – 15 amps
Amperage – 11 amps
Maximum power – 3600 watts
Climatic class – N
6 ft (2m) cord provided on icemaker

CAUTION

• Plug must be provided by the end-user and must conform to standard EN 60 335-2-24:2003 of the end

destination

• If the supply cord is damaged, it must be replaced by the manufacturer or their service agent, or a similarly

qualified technician in order to avoid a hazard

Plumbing

3/8" OD push-in water inlet
3/4" MPT drain
1/4" FPT condenser inlet (water-cooled condenser only)
1/4" FPT condenser drain (water-cooled condenser only)

Notes: 3/4" vented drain line must slope a minimum of 1/4" per foot (6mm per 30.4cm run).

Drain to be hard piped and insulated.

To prevent back flow, do not connect drains.

Separate drains for icemaker and condenser.

Water shut-off recommended within 10 feet (3m).

Follett recommends installation of Follett model 00130286 activated carbon filter

in icemaker inlet water line.

Ambient

Air temperature

100˚F/38˚C max.

50˚F/10˚C min.

Water temperature

90˚F/32˚C max.

45˚F/7˚C min.

Water pressure – potable

70 psi max. (483 kPa)

10 psi min. (69 kPa)

Note: Water-cooled condenser pressure 150 psi max (1034kPa); 10 psi min (69kPa)

Heat rejection

Air-cooled rejects 11,300 BTU/hr
Water-cooled rejects 12,800 BTU/hr

Ice production

F

C

50

10

60

16

70

21

80

27

90

32

60

16

1110

504

1054

478

1019

463

979

444

916

416

70

21

1017

462

948

430

887

403

875

397

787

357

80

27

890

404

822

373

770

350

715

325

656

298

90

32

761

346

738

335

715

325

671

305

600

273

100

38

731

332

665

302

624

283

577

262

521

237

lbs

kg

lbs

kg

lbs

kg

lbs

kg

lbs

kg

Inlet W

a

ter T

emper

atur

e F/C

Ambient Air Temperature F/C

Air-cooled icemaker capacity/24 hrs.

F

C

50

10

60

16

70

21

80

27

90

32

60

16

1004

456

965

438

919

417

837

380

781

355

70

21

969

440

919

417

879

399

813

369

773

351

80

27

908

412

852

387

817

371

764

347

746

339

90

32

818

371

766

348

734

333

684

311

676

307

100

38

695

316

663

301

630

286

567

258

534

243

lbs

kg

lbs

kg

lbs

kg

lbs

kg

lbs

kg

Water-cooled icemaker capacity/24 hrs.

Inlet W

a

ter T

emper

atur

e F/C

Ambient Air Temperature F/C