background image

38

Connections

Connect the signal and power cables, the
ground wire and optional equipment as
shown in Figure 5-14.

Figure 5-14 Display unit, rear view

RP

HDG

NMEA

DJ-1

OPTION

MARINE RADAR

TYPE
SER.NO.
DATE
COMPASS SAFE DISTANCE
STD

M STEER

M

EQUPMENT CLASS
FURUNO ELECTRIC CO., LTD

10.2-31.2VDC

3 GND

1

2

Signal cable connector

Connect signal cable

from antenna here.

NMEA connector
Connect navaid
nere.

HDG connector
Connect heading
sensor nere.

Covered.
(not use)

Power cable connector

Connect power

cable here.

Ground terminal

Connect ground wire between

here and ship's ground.

OPTION connector
Connect navaid,
video sounder, etc.
here.

CAUTION

Tigthen the boot-boud securely to ensure
watertightness. See page 44.