2 general troubleshooting (cont.) – Frymaster YPF95 User Manual
Page 20
YPF95 SERIES PORTABLE FILTRATION SYSTEMS
CHAPTER 6: TROUBLESHOOTING
6-2
6.2 General Troubleshooting (cont.)
Pump won't
start.
-
Tripped circuit breaker.
-
Incorrect or no line voltage.
Pump stops
during filtering
process.
-
Allow filter unit to cool for at least 45 minutes and
then press the pump reset button on the side of the
filter.
-
Turn filter pump "OFF". Allow oil to cool then empty
pan. Verify filter paper is clean and properly
installed. Refill pan and restart process.
Pump starts
and abruptly
stops.
-
Reset circuit breaker.
-
Pump is blocked or wiring is loose. Call FASC for
service.
-
Filter pan suction tube is blocked. Use a thin, flexible
wire to unclog.
-
Motor failed; call FASC for service.
Pumping is
erratic.
-
Verify that filter paper is properly installed under
hold-down ring.
Oil not being
returned to
frypot.
-
Solidified oil or sediment is likely clogging the filter
hose. Clear hose.
-
Clogged filter paper. Scrape off excess sediment or
replace filter paper.