Specifications

Electrical

Each icemaker requires its own separate circuit with electrical disconnect within 10 ft (6m).
Equipment ground required.
Standard electrical – 220-240/50/1
Maximum icemaker fuse – 20 amps
Amperage – 16 amps
Maximum power – 5280 watts
Climatic class – N
6 ft (2m) cord provided on icemaker

CAUTION

• Plug must be provided by the end-user and must conform to standard EN 60 335-2-24:2003 of the end

destination

• If the supply cord is damaged, it must be replaced by the manufacturer or their service agent, or a similarly

qualified technician in order to avoid a hazard

Plumbing

3/8" OD push-in water inlet
3/4" MPT drain
1/4" FPT condenser inlet (water-cooled condenser only)
1/4" FPT condenser drain (water-cooled condenser only)

Notes: 3/4" vented drain line must slope a minimum of 1/4" per foot (6mm per 30.4cm run).

Drain to be hard piped and insulated.

To prevent back flow, do not connect drains.

Separate drains for icemaker and condenser.

Water shut-off recommended within 10 feet (3m).

Follett recommends installation of Follett model 00130286 activated carbon filter

in icemaker inlet water line.

Ambient

Air temperature

100˚F/38˚C max.

50˚F/10˚C min.

Water temperature

90˚F/32˚C max.

45˚F/7˚C min.

Water pressure – potable

70 psi max. (483 kPa)

10 psi min. (69 kPa)

Note: Water-cooled condenser pressure 150 psi max (1034kPa); 10 psi min (69kPa)

Heat rejection

Air-cooled rejects 15,500 BTU/hr to air (3906Kcal/hr) to air
Water-cooled rejects 15,500 BTU/hr to water (3906Kcal/hr) to water

Ice production

F

C

50

10

60

16

70

21

80

27

90

32

60

16

1362

618

1290

586

1219

553

1148

521

1077

489

70

21

1290

586

1206

548

1136

516

1065

484

993

451

80

27

1192

541

1120

509

1050

477

919

417

907

412

90

32

1105

502

1033

469

969

440

891

405

820

372

100

38

989

449

917

416

847

385

776

352

714

324

lbs

kg

lbs

kg

lbs

kg

lbs

kg

lbs

kg

Inlet W

a

ter T

emper

atur

e F/C

Ambient Air Temperature F/C

Air-cooled icemaker capacity/24 hrs.

F

C

50

10

60

16

70

21

80

27

90

32

50

10

1128

512

1081

491

1035

470

989

449

943

428

60

16

1128

512

1081

491

1035

470

989

449

943

428

70

21

1128

512

1081

491

1035

470

989

449

943

428

80

27

1128

512

1081

491

1035

470

989

449

943

428

90

32

1128

512

1081

491

1035

470

989

449

943

428

lbs

kg

lbs

kg

lbs

kg

lbs

kg

lbs

kg

Water-cooled icemaker capacity/24 hrs.

Inlet W

a

ter T

emper

atur

e F/C

Ambient Air Temperature F/C