Specifications, Electrical, Caution – Follett HCE1400W User Manual
Page 5: Plumbing, Ambient, Heat rejection, Ice production
5
Specifications
Electrical
Each icemaker requires its own separate circuit with electrical disconnect within 10 ft (6m).
Equipment ground required.
Standard electrical – 220-240/50/1
Maximum icemaker fuse – 20 amps
Amperage – 16 amps
Maximum power – 5280 watts
Climatic class – N
6 ft (2m) cord provided on icemaker
CAUTION
• Plug must be provided by the end-user and must conform to standard EN 60 335-2-24:2003 of the end
destination
• If the supply cord is damaged, it must be replaced by the manufacturer or their service agent, or a similarly
qualified technician in order to avoid a hazard
Plumbing
3/8" OD push-in water inlet
3/4" MPT drain
1/4" FPT condenser inlet (water-cooled condenser only)
1/4" FPT condenser drain (water-cooled condenser only)
Notes: 3/4" vented drain line must slope a minimum of 1/4" per foot (6mm per 30.4cm run).
Drain to be hard piped and insulated.
To prevent back flow, do not connect drains.
Separate drains for icemaker and condenser.
Water shut-off recommended within 10 feet (3m).
Follett recommends installation of Follett model 00130286 activated carbon filter
in icemaker inlet water line.
Ambient
Air temperature
100˚F/38˚C max.
50˚F/10˚C min.
Water temperature
90˚F/32˚C max.
45˚F/7˚C min.
Water pressure – potable
70 psi max. (483 kPa)
10 psi min. (69 kPa)
Note: Water-cooled condenser pressure 150 psi max (1034kPa); 10 psi min (69kPa)
Heat rejection
Air-cooled rejects 15,500 BTU/hr to air (3906Kcal/hr) to air
Water-cooled rejects 15,500 BTU/hr to water (3906Kcal/hr) to water
Ice production
F
C
50
10
60
16
70
21
80
27
90
32
60
16
1362
618
1290
586
1219
553
1148
521
1077
489
70
21
1290
586
1206
548
1136
516
1065
484
993
451
80
27
1192
541
1120
509
1050
477
919
417
907
412
90
32
1105
502
1033
469
969
440
891
405
820
372
100
38
989
449
917
416
847
385
776
352
714
324
lbs
kg
lbs
kg
lbs
kg
lbs
kg
lbs
kg
Inlet W
a
ter T
emper
atur
e F/C
Ambient Air Temperature F/C
Air-cooled icemaker capacity/24 hrs.
F
C
50
10
60
16
70
21
80
27
90
32
50
10
1128
512
1081
491
1035
470
989
449
943
428
60
16
1128
512
1081
491
1035
470
989
449
943
428
70
21
1128
512
1081
491
1035
470
989
449
943
428
80
27
1128
512
1081
491
1035
470
989
449
943
428
90
32
1128
512
1081
491
1035
470
989
449
943
428
lbs
kg
lbs
kg
lbs
kg
lbs
kg
lbs
kg
Water-cooled icemaker capacity/24 hrs.
Inlet W
a
ter T
emper
atur
e F/C
Ambient Air Temperature F/C