Refrigeration system – Follett HCE1400W User Manual
Page 23
23
thermostatic
expansion
valve
compressor
High pressure vapor
High pressure liquid
Low pressure liquid
Low pressure vapor
low side
service port
high side
service port
condenser
filter dryer
high side
refrigeration
line run
low side
refrigeration
line run
Refrigeration system diagram
Refrigeration system
Refrigerant pressure data
Air
temperature
Air-cooled condensers
60˚F/16˚C 70˚F/21˚C 80˚F/27˚C 90˚F/32˚C 100˚F/38˚C
Pressure
208/26psi 238/28psi 270/30psi 306/33psi 346/36psi
discharge/suction
1435/180kPa 1641/194kPa 1862/207kPa 2110/228kPa 2386/249kPa
14.35/1.80bar
16.41/19.4bar
18.62/2.07bar
21.10/2.28bar
23.86/2.49bar
Water
temperature
Water-cooled condensers
60˚F/16˚C 70˚F/21˚C 80˚F/27˚C 90˚F/32˚C 100˚F/38˚C
Pressure
282/31psi 282/31psi 282/31psi 284/32psi 284/32psi
discharge/suction
1945/214kPa 1945/214kPa 1945/214kPa 1959/221kPa 1959/221kPa
19.45/2.14bar
19.86/2.14bar
19.86/2.14bar
19.59/2.21bar
19.59/2.21bar
Note: The water control valve is factory set to maintain 288 ± 15 psi discharge pressure @ 70˚F water.
The water control valve is factory set to maintain 1986 ± 103kPa discharge pressure @ 21˚C water.