7.2.4

DRAIN OPEN message
remains after closing drain
valve.

1. Computer was turned OFF while draining

frypot.

2. Close drain valve. Turn computer OFF

and ON again. Computer display will
read ON.

3. Open drain valve. Computer display

will read

DRAIN OPEN. After 30

seconds the computer display will read
FILL.

4. Close drain valve.

5. Fill frypot with shortening. Press

EXIT/COOL FILTER when ready to
cook.

6. If the computer message

DRAIN

OPEN remains after Steps 1-4, contact
an authorized service agent. Possible
malfunctions are:

a. Drain microswitch may be faulty.

b. Drain circuit is suspect.

c. Computer is suspect.

7.2.5

Pump motor won’t start or
stops during filtering.

1. The motor thermal overload or the 10 amp

circuit breaker has tripped. If the thermal
overload trips, wait approximately 45
minutes. Press the button on the end of the
filter motor. If the 10 amp circuit breaker
trips, reset it (located under the control
panel of the right-had fryer).

2. If you have to do this repeatedly, stop

resetting the overload or circuit breaker
and contact an authorized service agent.

NOTE: This is usually caused by allowing
large particles of food to enter the pump
during filtering. Ensure that the filter paper
and crumb screen are properly in place.