Frymaster Single Under Fryer Filter (SUFF) User Manual
Page 28

SUFF/UFF FILTRATION SYSTEMS
CHAPTER 3: INSTALLATION AND OPERATION
3-20
3.4.3 Hose and Wand Operation (cont.) 
 
4. If the quick-disconnect is under positive 
pressure (no ON/OFF valve), the oil will start 
to flow immediately into the frypot. If the 
flush valve is operated with a blue handle, 
pull the handle out to start oil flowing. Keep 
the wand inside the frypot at all times 
while the filter pump is activated. 
 
 
 
 
 
 
 
 
 
5. Rinse debris from the frypot into the filter 
pan with the wand. When cleanup is 
complete, push in the blue handle (if 
applicable), close the drain valve (red 
handle), and turn the auxiliary switch OFF. 
Allow hose/wand to drain into the filter pan. 
 
 
 
 
 
 
 
 
 
6. Refill the frypot by pulling the yellow handle 
to open the oil-return valve (this activates the 
filter pump automatically). 
 
 
 
 
 
 
 
 
 
 
 
 
 
Pulling the blue handle opens the flush valve on 
fryers so equipped. 
Use the wand to rinse debris from the frypot into 
the filter pan. Maintain a firm grip on the wand 
handle at all times.
Return filtered oil to the frypot by pulling yellow 
handle to open oil return valve. 