3.4 Operating the Filter
 
3.4.1 Pan Preparation and Operation 
 
See Section 3.2.1, Assembling the Filter, and Section 3.2.2, Installing the Filter, for the appropriate 
filter preparation procedure. 
 
CAUTION
NEVER operate the filter unit unless cooking oil is
at operating temperature (~350°F/ ~177°C).
 
1. Ensure the filter pan assembly is prepared as described in Section 3.2.1, Assembling the Filter, 
and turn fryer off.
 
2. Remove fry baskets from frypot and skim any 
large debris from the oil. Use extreme 
caution, as oil is at or near operating 
temperature (~350°F/~177°C). 
 
 
 
 
 
 
 
 
 
 
3. Remove the support grid from the frypot 
using the clean-out rod. Stir the oil with the 
frypot/filter brush to suspend debris prior to 
draining. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Prior to filtering, skim any large debris from oil in 
frypot. 
Removing support grid from fry vessel prior to 
filtering. 