Installing countertop dispensers – Follett 110 Series User Manual
Page 8
Installing countertop dispensers
1.
Position dispenser in desired location, mark
dispenser outline on counter and remove dispenser.
2. Drill four 5mm (3/8") holes in counter (Fig. 2) to
anchor dispenser to counter.
Follett countertop dispensers can have any or all
utilities run directly through counter or out rear of
dispenser. For dispensers with any utilities exiting
through counter, make counter cut-out as shown
in Fig. 2.
3. If ice transport tube will exit out rear of dispenser,
remove ice transport tube knock-out (Fig. 5G) from
rear of dispenser.
Note: Utility connections can be accessed through
front of dispenser by removing stainless steel splash
panel on front of dispenser, or by removing access
panel (Figs. 4, 5) on back of dispenser.
4. If any electric utilities or water line will be connected
through rear of dispenser, remove utility knock-out
(Fig. 5H) from rear of dispenser and install supplied
protective grommet.
5. If power is to be supplied through counter cut-out,
complete steps 6-9. If power is to be supplied through
rear of dispenser, proceed to step 10.
6. Temporarily remove rear access panel (Figs. 4, 5)
from rear of dispenser.
7. Loosen junction box mounting screws. Lift junction
box and power cord up until cord and mounting
screws clear notches on rear panel of dispenser.
Remove Phillips head screws from right side of
junction box.
8. Rotate junction box 90 degrees so that screw holes
on right side of junction box align with holes on rear
dispenser panel. Resecure junction box to dispenser
using Phillips head screws.
9. Place power cord inside dispenser and replace
access panel (Figs. 4 and 5) on rear of dispenser.
Note: For dispensers installed with utilities connected
through rear of dispenser, it may be easier to make
preliminary connections before dispenser is set in
place.
8
622mm
603mm
167mm
441mm
543mm
3/8"
311mm
13mm (.5")
41mm (1.625")
13mm (.5")
227mm x 356mm (9" X 14")
DRAIN PAN
CUT OUT
(
21.375"
)
(6.54")
(
17.375"
)
(
24.5"
)
(
23.75"
)
(
12.25"
)
Fig. 2 – Counter cut-out, all models
(J) 3/8" FPT
water inlet
(L) alternate 3/4"
dispenser drain
location
drain pan
(K) 3/4" FPT
dispenser drain
Dispensers with top mount icemakers cannot be mounted on legs. They must be bolted to counter.
Use gloves when lifting icemaker to protect hands from sheet metal edges.
!
Fig. 3 – Top view, dispenser plumbing connections
countertop and wall mount units with drain pan