Maintenance
1 5
Travis Industries
9 3 5 0 8 0 9 1
2 2 0 6 0 2
Twice Yearly Maintenance
Check Firebrick, Baffle
With the fireplace completely cool, remove ash from the firebox (see the instructions on the previous
page) and check the firebrick and baffle.
Make sure the firebrick is intact.
The baffle should be intact - some
warping and flaking is not uncommon. It
rests on three tabs at the rear of the
firebox and should be pushed all the
way back. NOTE: the bend should go
upwards.
Door Switch (turns blower off
when doors are opened)
Serial Number Label
Clean the Combustor
With the fireplace completely cool (at least two hours after the last coal has extinguished), use a
vacuum cleaner to draw all ash from the catalytic combustor (see the illustration below).
The catalytic combustor is located
above the firebox. It can be seen by
looking from below with the doors open.
To clean the combustor, use a vacuum
cleaner to suck out ash and other
deposits inside the square holes of the
combustor. The brush attachment is
especially effective in removing ash.
WARNING: The combustor becomes
extremely hot during operation. Wait at
least two hours after the last coal has
extinguished before cleaning.
Clean the Blower Filter
The remote blower has a removable cover to allow for cleaning of the filter. This filter can be removed
and washed to clean dust and debris. See the directions to the right to remove the filter.
Remove the four
screws that go into
these holes.
Shake the filter to remove any
dirt that may have accumulated.
Intake Grill
Blower
Housing
Filter Screen
Filter
1/4" Nutdriver