beautypg.com

Maintenance 1 5, Twice yearly maintenance, Check firebrick, baffle – FireplaceXtrordinair Elite Fireplacextrodin 36-Elite User Manual

Page 17: Clean the combustor, Clean the blower filter

background image

Maintenance

1 5

Travis Industries

9 3 5 0 8 0 9 1

2 2 0 6 0 2

Twice Yearly Maintenance

Check Firebrick, Baffle

With the fireplace completely cool, remove ash from the firebox (see the instructions on the previous
page) and check the firebrick and baffle.

Make sure the firebrick is intact.

The baffle should be intact - some
warping and flaking is not uncommon. It
rests on three tabs at the rear of the
firebox and should be pushed all the
way back. NOTE: the bend should go
upwards.

Door Switch (turns blower off
when doors are opened)

Serial Number Label

Clean the Combustor

With the fireplace completely cool (at least two hours after the last coal has extinguished), use a
vacuum cleaner to draw all ash from the catalytic combustor (see the illustration below).

The catalytic combustor is located

above the firebox. It can be seen by

looking from below with the doors open.

To clean the combustor, use a vacuum

cleaner to suck out ash and other

deposits inside the square holes of the

combustor. The brush attachment is

especially effective in removing ash.

WARNING: The combustor becomes

extremely hot during operation. Wait at

least two hours after the last coal has

extinguished before cleaning.

Clean the Blower Filter

The remote blower has a removable cover to allow for cleaning of the filter. This filter can be removed
and washed to clean dust and debris. See the directions to the right to remove the filter.

Remove the four
screws that go into
these holes.

Shake the filter to remove any
dirt that may have accumulated.

Intake Grill

Blower
Housing

Filter Screen

Filter

1/4" Nutdriver