C – 1
APPENDIX C
C.1
Option
Name
Specfication
Scanner
feature
IPC-2
CA01952-0191
M3096EX
Image processing
M3096GX
• Automatic separation
• Image emphasis
• Outline extraction
• Mirror image
• Dynamic threshold
• Noise removing
• Smoothing
CMP-2
CA01952-0196
M3096GX
• 4Mbyte memory
• MH/MR/MMR compression
Contact your Fujitsu sales agent for more information
C.2
IPC-2/CMP-2 option board installation
WARING: Follow the outlined procedure to avoid danger from electrical components.
(1)
Verify that the scanner power is turned off.
(2)
Remove the AC cable from the year of the scanner.
(3)
Remove the two screws securing the power supply and the interface PCA assembly. Pul
out the assembly slighly using the tab in the direction shown by the arrow.
CAUTION: Do not pull on the flat cable too strongly or it may be damaged.
Tab
screws
flat cable
(inside)