beautypg.com

Burner and nozzle characteristics – Indesit KJ1G1 User Manual

Page 17

background image

17

remove the knob and adjust the regulation screw, which
is positioned in or next to the tap pin, until the flame is
small but steady.
N.B.: in the case of liquid gas, the regulation screw
must be screwed in to the bottom.

check that the flame does not turn off when you turn
the tap quickly from high to low.

d Regulating the primary air of the burners:
The primary air of the burners requires no regulation.
Important

On completion of the operation, replace the old rating
sticker with one indicating the new type of gas used. This
sticker is available from our Service Centres.
Note
Should the pressure of the gas used be different (or vary)
from the recommended pressure, it is necessary to fit a
suitable pressure regulator onto the inlet pipe in
compliance with current National Regulations relative to
“regulators for channelled gas”.

*

At 15°C and 1013 mbar- dry gas

**

Propane

P.C.S. = 50,37 MJ/Kg

***

Butane

P.C.S. = 49,47 MJ/Kg

Natural

P.C.S. = 37,78 MJ/m

3

Burner and nozzle characteristics

S S

R

A

KJ1G1/R

Table 1

Liquid Gas

Natural Gas

Burner

Diameter

(mm)

Thermal Power

kW (p.c.s.*)

By-Pass

1/100

Nozzle

1/100

Flow*

g/h

Nozzle

1/100

Flow*

l/h

Nozzle

1/100

Flow*

l/h

Nominal Reduced

(mm)

(mm)

***

**

(mm)

(mm)

Fast
(Large)(R)

100

3.00

0.7

41

87

218

214

128

286

143

286

Semi Fast
(Medium)(S)

75

1.90

0.4

30

70

138

136

104

181

118

181

Auxiliary

(Small)(A)

51

1.00

0.4

30

52

73

71

76

95

80

95

Supply

Pressures

Nominal (mbar)

Minimum (mbar)

Maximum (mbar)

28-30

20
35

37
25
45

20
17
25

13

6,5

18