FUJITSU MCM3064AP User Manual
Page 144

Host Interface
4-74
C156-E227-01EN
Additional Sense Code (ASC)/Additional Sense Code Qualifier (ASCQ) indicates
detailed error information. The definition of ASC/ASCQ is shown in Table 4.103.
Table 4.103 ASC/ASCQ list (1/2)
Sense
Key
ASC
ASCQ
Error description
2
04
00
LOGICAL UNIT NOT READY, CAUSE NOT REPORTABLE
2
04
04
LOGICAL UNIT NOT READY, FORMAT IN PROGRESS
3
09
00
TRACK FOLLOWING ERROR
4
08
03
LOGICAL UNIT COMMUNICATION CRC ERROR
3
09
01
TRACKING SERVO ERROR
3
0C
00
WRITE ERROR
3
0C
02
WRITE ERROR/AUTO REALLOCATION FAILED
3
10
00
ID CRC ERROR
3
11
00
UNRECOVERED READ ERROR
3
15
02
POSITIONING ERROR DETECTED BY READ OF MEDIUM
1
17
06
RECOVERED DATA WITHOUT ECC/DATA AUTO
REALLOCATED
1
18
00
RECOVERED DATA WITH ERROR CORRECTION & RETRIES
APPLIED
1
19
00
DEFECT LIST ERROR
3
19
01
DEFECT LIST NOT AVAILABLE
3
19
02
DEFECT LIST ERROR IN PRIMARY LIST
3
19
03
DEFECT LIST ERROR IN SECONDARY LIST
1
1C
00
DEFECT LIST NOT FOUND
5
20
00
INVALID COMMAND OPERATION CODE
5
21
00
LOGICAL BLOCK ADDRESS OUT RANGE
5
24
00
INVALID FIELD IN COMMAND PACKET
5
25
00
LOGICAL UNIT NOT SUPPORTED
5
26
00
INVALID FIELD IN PARAMETER LIST
7
27
00
WRITE PROTECTED
6
28
00
NOT READY TO READY TRANSITION, MEDIUM MAY HAVE
CHANGED
6
29
00
POWER ON, RESET, DEVICE RESET OCCURRED